APC AP7922

APC AP7922 32A 230V Switched Rack PDU User Manual

Model: AP7922 | Brand: APC by Schneider Electric

Танилцуулга

This manual provides essential instructions for the safe installation, operation, and maintenance of your APC AP7922 32A 230V Switched Rack PDU. The AP7922 is a rack-mountable power distribution unit designed to provide advanced power control and monitoring capabilities for IT equipment in data centers and server rooms. It features AC 230V input, Ethernet 10/100 connectivity, and 16 output connectors, all within a 2U, 19-inch form factor.

Аюулгүй байдлын чухал мэдээлэл

Please read and understand all safety instructions before installing or operating this equipment. Failure to follow these instructions could result in electric shock, fire, or serious injury.

  • Энэ төхөөрөмж нь зөвхөн дотор ашиглах зориулалттай.
  • Connect the PDU to a properly grounded power source.
  • Do not attempt to open or service the PDU. Refer all servicing to qualified personnel.
  • Ensure the total current draw of connected equipment does not exceed the PDU's maximum current rating (32 Amps).
  • Засвар үйлчилгээ, суурилуулалт хийхээс өмнө цахилгааныг салга.

Багцын агуулга

Савлахдаа бүх зүйл байгаа эсэхийг шалгана уу:

  • APC AP7922 Switched Rack PDU
  • Суулгах гарын авлага
  • Тавиурын бэхэлгээний бэхэлгээ
  • Serial configuration cable
  • Баримт бичгийн CD

Бүтээгдэхүүний онцлог

The APC AP7922 Switched Rack PDU offers the following key features:

  • Шилжүүлсэн залгуурууд: Remotely control power to individual outlets for power cycling, delayed sequencing, and load shedding.
  • Сүлжээний удирдлага: Full-featured network management interface via Ethernet 10/100 for remote monitoring and control.
  • Одоогийн хяналт: Monitor the aggregate current draw per PDU to prevent circuit overloads.
  • Тавиурт суурилуулах загвар: Occupies 2U of rack space, compatible with standard 19-inch racks.
  • Гаралтын холбогч: Equipped with 16 C13 output connectors.
  • Оролтын хэмжээtage: Supports AC 230V input.
APC AP7922 Switched Rack PDU front view with outlets and network port

Зураг: Урд view of the APC AP7922 Switched Rack PDU, showing the 16 C13 outlets and network interface.

Тохируулах заавар

1. Rack Mounting

  1. Identify two available 2U spaces in your standard 19-inch equipment rack.
  2. Attach the provided rack-mounting brackets to the PDU using the screws supplied.
  3. Secure the PDU into the rack using appropriate rack screws. Ensure it is firmly seated and level.

2. Эрчим хүчний холболт

  1. Connect the PDU's input power cord to a dedicated 230V, 32A power source. Ensure the power source is properly grounded.
  2. Do not overload the circuit. Verify that the total load of connected devices will not exceed 32 Amps.

3. Сүлжээний холболт

  1. Connect a standard Ethernet cable from the PDU's network port to your network switch or router.
  2. The PDU will obtain an IP address via DHCP by default. Refer to the full user manual for static IP configuration.

Ашиглалтын заавар

Powering On/Off Connected Devices

Once the PDU is powered and connected to the network, you can manage its outlets remotely.

  1. Access the PDU's web a-д IP хаягаа оруулснаар интерфейс web хөтөч.
  2. Log in using the default credentials (refer to the full manual for details).
  3. Navigate to the outlet control section. From here, you can individually switch on, switch off, or cycle power to each of the 16 C13 outlets.

Monitoring Current Draw

The web interface also provides real-time monitoring of the aggregate current draw. This allows you to ensure that the PDU and its connected circuit are not overloaded.

Засвар үйлчилгээ

  • Цэвэрлэгээ: Periodically clean the exterior of the PDU with a soft, dry cloth. Do not use liquid cleaners or solvents.
  • Програм хангамжийн шинэчлэлтүүд: Check the APC website for available firmware updates to ensure optimal performance and security. Follow the instructions provided with the firmware package for safe updating.
  • Кабелийн менежмент: Ensure all power and network cables are neatly routed and secured to prevent accidental disconnections or damage.

Алдааг олж засварлах

АсуудалБоломжит шалтгаанШийдэл
PDU does not power on.No input power; tripped circuit breaker.Verify the power cord is securely connected. Check the building's circuit breaker for the PDU's power source.
Нэвтрэх боломжгүй web интерфейс.Incorrect IP address; network connectivity issue; PDU not powered.Ensure the PDU is powered on. Verify network cable connection. Confirm the correct IP address. Check network settings.
Outlets do not switch.Software issue; PDU fault.Try restarting the PDU. If the issue persists, contact technical support.
Хэт ачааллын дохиолол.Total current draw exceeds PDU rating.Disconnect non-essential equipment to reduce the load. Redistribute equipment across multiple PDUs if necessary.

Техникийн үзүүлэлтүүд

ОнцлогДэлгэрэнгүй
Загварын дугаарAP7922
БрэндSchneider Electric компанийн APC
Form Factor2U Rack-mountable, 19-inch
Оролтын хэмжээtage230 вольт хувьсах гүйдэл
Оролтын гүйдэл32 Amps
Гаралтын ботьtage230 вольт хувьсах гүйдэл
Гаралтын гүйдэл32 Amps (хамгийн их)
Гаралтын тоо16
Холбогч төрөлC13
Сүлжээний интерфейсEthernet 10/100
Ватtage7360 ватт
Хэмжээ (H x W x D)4.49 x 17.52 x 3.5 инч
Жин0.7 кг
МатериалМеталл
ӨнгөХар

Баталгаат болон дэмжлэг

Баталгаат хугацааны мэдээлэл

APC products typically come with a standard manufacturer's warranty. Please refer to the warranty card included with your product or visit the official APC website for detailed warranty terms and conditions specific to the AP7922 model.

Техникийн дэмжлэг

For technical assistance, troubleshooting, or to report issues, please contact APC customer support. You can find contact information and additional resources on the official Schneider Electric webсайт:

APC by Schneider Electric Official Webсайт

© 2023 APC by Schneider Electric. All rights reserved. Information in this document is subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.