Danfoss 034L0097

Danfoss KVR15 Pressure Regulator Instruction Manual

Загвар: 034L0097

1. Танилцуулга

This manual provides essential information for the safe and efficient installation, operation, and maintenance of the Danfoss KVR15 Pressure Regulator. The KVR15 is designed to maintain a constant evaporating pressure in refrigeration and air conditioning systems. It features a 5/8 inch ODF connection and an access port for pressure measurement.

Please read this manual thoroughly before installing or operating the unit. Keep this manual for future reference.

2. Аюулгүй байдлын мэдээлэл

WARNING: Improper installation, operation, or maintenance can result in serious injury or equipment damage.

3. Багцын агуулга

Савлахдаа бүх бүрэлдэхүүн хэсгүүд байгаа бөгөөд гэмтэлгүй эсэхийг шалгана уу:

Danfoss KVR15 Pressure Regulator with 5/8 inch ODF connections and an access port

Image: Danfoss KVR15 Pressure Regulator. This image shows the compact design of the regulator, highlighting its 5/8 inch ODF connections on both ends and a small access port located on the side for pressure monitoring.

4. Тохиргоо ба суурилуулалт

Follow these steps for proper installation of the KVR15 Pressure Regulator:

  1. Системийн бэлтгэл: Ensure the refrigeration system is depressurized and isolated before beginning installation.
  2. Байршил: Install the regulator in the suction line, upstream of the compressor, and preferably in a horizontal pipe run. Ensure there is sufficient space for service and adjustment.
  3. Холболт: The KVR15 features 5/8 inch ODF (Outside Diameter Flare) connections. Use appropriate brazing techniques for copper tubing. Ensure the regulator is clean and free of debris before brazing. Protect the valve body from excessive heat during brazing by wrapping it with a wet cloth or using a heat sink compound.
  4. Урсгалын чиглэл Observe the arrow on the regulator body, which indicates the correct flow direction. Install the regulator so that the refrigerant flows in the direction of the arrow.
  5. Хандалтын порт: The access port allows for pressure measurement. Ensure the cap is securely tightened after use to prevent leaks.
  6. Битүүмжлэх туршилт: After installation, perform a thorough leak test on all connections using an appropriate leak detection method.
  7. Нүүлгэн шилжүүлэх: Evacuate the system to the required vacuum level before charging with refrigerant.

Санал болгож буй хэрэгслүүд: Brazing torch, nitrogen for purging, leak detector, vacuum pump, manifold gauge set, pipe cutters, deburring tool, wet rags or heat sink compound.

5. Ашиглалтын заавар

The KVR15 regulator is designed to maintain a constant evaporating pressure. Adjustment is typically performed during system commissioning.

  1. Анхны тохиргоо: The regulator is factory set to a nominal pressure. For specific system requirements, adjustment may be necessary.
  2. Даралтыг тохируулах:
    • Remove the protective cap from the adjustment spindle.
    • Turn the adjustment spindle clockwise to increase the evaporating pressure.
    • Turn the adjustment spindle counter-clockwise to decrease the evaporating pressure.
    • Use a pressure gauge connected to the access port or elsewhere in the suction line to monitor the pressure while adjusting.
    • Make small adjustments and allow the system to stabilize before making further changes.
    • Once the desired pressure is achieved, replace and tighten the protective cap to secure the setting and prevent leaks.
  3. Access Port Usage: The access port allows for temporary connection of a pressure gauge to verify the regulated pressure. Always ensure the port cap is securely tightened when not in use.

6. Засвар үйлчилгээ

The Danfoss KVR15 Pressure Regulator is designed for long-term, reliable operation with minimal maintenance. However, periodic checks are recommended.

Жич: Internal components of the KVR15 are not user-serviceable. If the regulator malfunctions, it should be replaced by a qualified technician.

7. Алдаа засах

This section provides solutions to common issues that may arise with the KVR15 Pressure Regulator.

АсуудалБоломжит шалтгаанШийдэл
Regulated pressure is too high/low.Incorrect adjustment setting.Adjust the regulator setting as described in the "Operating Instructions" section.
Pressure fluctuates significantly.System instability; debris in regulator; incorrect sizing.Check for system issues (e.g., TXV operation). If debris is suspected, the regulator may need replacement. Verify regulator sizing for the application.
Refrigerant leak at connections.Improper brazing; loose access port cap.Re-braze connections if necessary. Ensure access port cap is securely tightened.
No pressure regulation.Internal failure; completely clogged.The regulator may need to be replaced. Consult a qualified technician.

If troubleshooting steps do not resolve the issue, contact a qualified HVAC/R technician or Danfoss technical support.

8. Техникийн үзүүлэлтүүд

ОнцлогДэлгэрэнгүй
БрэндДанфосс
Загварын дугаар034L0097
ТөрөлEvaporating Pressure Regulator (KVR15)
Холболтын хэмжээ5/8 inch ODF (Outside Diameter Flare)
Хэмжилтийн системинч
ОнцлогуудПорт руу нэвтрэх
ҮйлдвэрлэгчДанфосс
ASINB0085POK2G
Эхний боломжтой огноо27 оны арванхоёрдугаар сарын 2017

9. Баталгаат хугацааны мэдээлэл

Danfoss products are manufactured to high-quality standards. This product is covered by Danfoss's standard manufacturer's warranty. Specific warranty terms and conditions, including duration and coverage details, can be found on the official Danfoss website or by contacting Danfoss customer service. Please retain your proof of purchase for warranty claims.

Жич: The warranty may be voided by improper installation, unauthorized modifications, or use outside of specified operating conditions.

10. Хэрэглэгчийн дэмжлэг

For technical assistance, spare parts, or further information regarding the Danfoss KVR15 Pressure Regulator, please visit the official Danfoss webсайтад зочлох эсвэл тэдний хэрэглэгчийн дэмжлэгийн хэлтэстэй холбогдоно уу.

Danfoss Official Webсайт: www.danfoss.com

When contacting support, please have your product model number (034L0097) and serial number (if applicable) ready.