Dataprobe iBoot-G2+

Dataprobe iBoot-G2+ Web Power Switch User Manual

Model: iBoot-G2+

Remote Power Control and Management Solution

Танилцуулга

The Dataprobe iBoot-G2+ is a web-enabled power switch designed for remote power control and management of connected devices. It features a single NEMA 5-15 circuit outlet, allowing users to remotely reboot, power on, or power off equipment from any location via a web browser or the iBoot Cloud Service. This device is ideal for managing remote servers, network equipment, or any device that benefits from automated power cycling to ensure continuous operation and minimize downtime. The iBoot-G2+ also includes two expansion I/O ports for custom integration with external sensors or alarms, providing enhanced flexibility for various applications.

Тохиргоо ба суурилуулалт

Багцын агуулга

iBoot-G2+ unit with included power and ethernet cables

Figure 1: iBoot-G2+ unit with standard accessories.

Физик холболт

  1. Эрчим хүчийг холбох: Plug the provided power cord into the A/C Input port on the iBoot-G2+ and then into a standard wall outlet.
  2. Сүлжээг холбох: Connect an Ethernet cable from your network router or switch to the Ethernet port on the iBoot-G2+. Ensure your network has DHCP enabled for automatic IP address assignment.
  3. Төхөөрөмжийг холбох: Plug the device you wish to control into the A/C Output port of the iBoot-G2+.
iBoot-G2+ with A/C Input, A/C Output, Ethernet, and USB ports visible

Figure 2: Rear and Front View of iBoot-G2+ showing A/C Input, A/C Output, Ethernet, and Expansion Ports.

Close-up of iBoot-G2+ A/C Output and Expansion Ports

Зураг 3: Нарийвчилсан view of the A/C Output and Expansion I/O Ports (EXP1, EXP2) on the iBoot-G2+.

Анхны тохиргоо (Web Интерфэйс)

Once connected, the iBoot-G2+ will obtain an IP address from your network's DHCP server. You can discover its IP address using the iBoot Discovery Tool (available on the Dataprobe website) or by checking your router's connected devices list.

  1. Нээлттэй a web browser and enter the iBoot-G2+'s IP address in the address bar.
  2. Log in using the default credentials (refer to the included quick start guide for default username and password).
  3. It is highly recommended to change the default password immediately for security purposes.
  4. Configure network settings (e.g., static IP, DNS) if required for your network environment.

Өргөтгөх оролт гаралтын портууд

The iBoot-G2+ features two expansion I/O ports (EXP1 and EXP2) for integrating external devices such as sensors or alarms. These ports allow for customized power management solutions based on external triggers. Refer to the advanced user guide on the Dataprobe website for detailed instructions on configuring and utilizing these ports.

Operating the iBoot-G2+

Алсын цахилгаан удирдлага

The primary function of the iBoot-G2+ is to provide remote control over the power to a connected device. This can be done via the web interface or the iBoot Cloud Service.

AutoPing Reboot Feature

The AutoPing feature allows the iBoot-G2+ to automatically monitor the responsiveness of a network device (e.g., a router or server) by continuously sending ping requests to a specified IP address. If the device fails to respond after a configurable number of attempts or duration, the iBoot-G2+ will automatically power cycle the connected equipment.

iBoot Cloud Service Access

Dataprobe offers a free iBoot Cloud Service that provides secure, centralized power control and monitoring for multiple iBoot devices from anywhere. This service simplifies management, especially for deployments with numerous iBoot units across different locations.

Diagram showing iBoot devices connected to a cloud service, controlled by a user via a computer

Figure 4: iBoot Cloud Service for centralized management.

Бодит цагийн сэрэмжлүүлэг

The iBoot-G2+ can send instant notifications via email or SMS for various events, including power status changes, automatic reboots, or network connectivity issues. This keeps you informed about the status of your connected equipment and the iBoot-G2+ itself.

Засвар үйлчилгээ

The iBoot-G2+ is designed for reliable, low-maintenance operation. Regular maintenance primarily involves ensuring proper ventilation and keeping the unit clean.

Алдааг олж засварлах

Нийтлэг асуудал ба шийдэл

АсуудалБоломжит шалтгаанШийдэл
iBoot-G2+ not accessible via web интерфейс.Incorrect IP address, network cable disconnected, DHCP issue, unit not powered on.Verify power and network cable connection. Use the iBoot Discovery Tool to find the IP address. Check router's DHCP client list. Ensure the unit is powered on (Outlet On LED should be lit).
Connected device does not power cycle.Device not properly plugged into iBoot-G2+ output, iBoot-G2+ not receiving power, AutoPing not configured correctly.Ensure the device is securely plugged into the A/C Output. Check iBoot-G2+ power. Review AutoPing settings in the web interface (target IP, ping interval, retry count).
AutoPing not working as expected.Incorrect target IP, network firewall blocking pings, device being pinged is truly unresponsive.Double-check the target IP address. Ensure no firewall rules are blocking ICMP (ping) traffic from the iBoot-G2+. Confirm the target device is indeed unresponsive.
Programmatic control (e.g., via command-line tool) is unreliable.Network latency, firewall issues, software version incompatibility.Ensure stable network connection. Check firewall settings on both the iBoot-G2+ and the controlling machine. Verify you are using the latest version of the control software. Consider using the web interface for critical operations if programmatic control is unstable.
Hostname not registering with DNS.Device firmware limitation, network DNS configuration.Access the device via its IP address directly. Check Dataprobe's support resources for firmware updates that may address this. Ensure your DNS server is configured to accept dynamic updates if applicable.

For further assistance, refer to the comprehensive user manual available on the Dataprobe website or contact Dataprobe technical support.

Үзүүлэлтүүд

ОнцлогДэлгэрэнгүй
Загварын дугаарiBoot-G2+
БрэндDataprobe
Гаралтын төрөлSingle NEMA 5-15 Circuit Outlet
Оролтын хэмжээtage105-125V, 60Hz, 12A Max / 210-240V, 50Hz, 10A Max (AC)
Өргөтгөх боомтууд2 I/O Ports (EXP1, EXP2)
ХолболтEthernet (RJ45)
Хэмжээ (LxWxH)3.2 x 4.2 x 2 инч
Жин1 фунт
ӨнгөХар
Эхний боломжтой огноо14 оны нэгдүгээр сарын 2013

Баталгаат хугацааны мэдээлэл

Dataprobe products are manufactured to high quality standards. For detailed warranty information, including terms, conditions, and duration, please refer to the warranty statement provided with your product or visit the official Dataprobe webсайт. Баталгаат нэхэмжлэл гаргахын тулд худалдан авалтаа нотлох баримтаа хадгалаарай.

Дэмжлэг ба холбоо барих

For technical support, product inquiries, or additional documentation, please visit the Dataprobe official webсайт эсвэл харилцагчийн үйлчилгээний хэлтэстэй холбогдоно уу.

Холбогдох баримт бичиг - iBoot-G2+

Урьдчилсанview Dataprobe iBoot-G2+ / iBoot-G2S Web Enabled Power Switch User Manual
This manual provides comprehensive instructions for the Dataprobe iBoot-G2+ and iBoot-G2S web-enabled power switches. It covers setup, operation, network configuration, expansion capabilities, cloud services, and command-line interface usage for remote power management and monitoring.
Урьдчилсанview Dataprobe iBoot-WiFi User Manual: Remote Power Control and Reboot
Comprehensive user manual for the Dataprobe iBoot-WiFi, a network-controlled AC power switch. Learn about remote power control, device rebooting, AutoPing, web interface, cloud services, and troubleshooting.
Урьдчилсанview Dataprobe iBoot-G2S Quick Start Guide: Setup, Configuration, and Mounting
A comprehensive quick start guide for the Dataprobe iBoot-G2S, detailing setup, network connection, IP address configuration via web browser or DMU, important safety instructions, and mounting options for wall or DIN rail installation.
Урьдчилсанview Dataprobe iBoot-PDU Quick Start Guide
Quick start guide for the Dataprobe iBoot-PDU, providing instructions on setup, IP address configuration, web browser control, and essential safety information for remote power distribution.