SJE Rhombus 1005481

SJE-Rhombus Tank Alert XT Дотор/Гадна савны дохиоллын хэрэглэгчийн гарын авлага

Model: 1005481 | Brand: SJE Rhombus

1. Танилцуулга

The SJE-Rhombus Tank Alert XT is an advanced indoor/outdoor alarm system designed to provide crucial audio and visual warnings for threatening liquid level conditions. This system is ideal for various applications including lift pump chambers, sump pump basins, holding tanks, sewage systems, agricultural uses, and other non-potable water environments. Its robust design ensures reliable operation and automatic reset functionality once the alarm condition is resolved.

SJE-Rhombus Tank Alert XT alarm unit and float switch

Зураг 1: The SJE-Rhombus Tank Alert XT system components. This image displays the gray alarm unit with a red beacon on top, a black float switch with its coiled cable, and a metal hose clamp along with two screws for mounting. The alarm unit features a "TANK ALERT XT" label, SJE-Rhombus logo, and a power/silence switch.

2. Үндсэн шинж чанарууд

3. Техникийн үзүүлэлтүүд

ТодорхойлолтДэлгэрэнгүй
Ботьtage120 VAC, 50/60 Гц, 7 ватт хамгийн их. (сэрүүлгийн нөхцөл)
Alarm Enclosure Dimensions16.51 x 11.43 x 7.62 см (6.5 x 4.5 x 3.0 инч)
Хаалтны төрөлIndoor/outdoor weatherproof thermoplastic, meets Type 3R water-tight standard
Сэрүүлгийн эвэр85 decibels at 3 meters (10 feet), meets Type 3R water-tight standard
Alarm BeaconMeets Type 3R water-tight standard
Туршилт/Чимээгүй солихCertified to IP66 and IP68 standards
Float Switch Cable Length4.57 meters (15 feet), flexible 18 gauge, 2 conductor (UL) SJOW
Хөвөгч материалHigh impact, corrosion resistant PVC housing
Float Operating Temperature60°C (140°F) хүртэл
Хөвөгч шилжүүлэгчийн төрөлHermetically sealed steel capsule with mercury-to-mercury contacts
Суурилуулах төрөлХанын бэхэлгээ
Зүйлийн жин2.99 фунт
Бүтээгдэхүүний хэмжээс6.5 x 3 x 4.5 инч

4. Тохиргоо ба суурилуулалт

Proper installation is crucial for the reliable operation of your Tank Alert XT system. It is recommended that installation be performed by a qualified electrician or technician in accordance with local electrical codes.

4.1. Бүрэлдэхүүн хэсгүүд дууссанview

4.2. Суулгах алхамууд

  1. Байршлыг сонгох: Choose a suitable indoor or outdoor location for the alarm enclosure. Ensure it is easily accessible for testing and silencing, and within reach of a 120 VAC power source. The enclosure is designed for wall mounting.
  2. Mount Alarm Enclosure: Securely mount the alarm enclosure to a flat surface using appropriate fasteners. Ensure it is level and stable.
  3. Install Float Switch:
    • Determine the desired alarm activation level within the tank or basin. The float switch should be positioned so it activates when the liquid reaches this critical level.
    • Өгөгдсөн холбох хэрэгслийг ашиглана ууamp to secure the float switch cable to the discharge pipe or a suitable mounting point inside the tank. Ensure the float can move freely up and down without obstruction.
    • Route the float switch cable back to the alarm enclosure, protecting it from damage.
  4. Утасны холболтууд:
    • АНХААРУУЛГА: Ensure power is disconnected before making any electrical connections.
    • Connect the float switch wires to the designated terminals inside the alarm enclosure as per the wiring diagram provided with the product packaging.
    • Connect the alarm unit to a dedicated 120 VAC power supply. For optimal safety and independent operation, it is recommended to connect the alarm to a separate circuit from the pump.
  5. Туршилтын систем: Once all connections are secure and power is restored, perform a system test. Manually raise the float switch to simulate a high liquid level. The alarm horn should sound, and the red beacon should activate. Use the silence switch to confirm it silences the horn, and then lower the float to confirm auto-reset.

5. Ашиглалтын заавар

The Tank Alert XT system is designed for straightforward operation, providing clear indications of liquid level conditions.

5.1. Дохиоллын идэвхжүүлэлт

When the liquid level in the tank or basin rises to the point where it activates the float switch, the alarm system will trigger:

5.2. Silencing the Alarm

To silence the audible horn, press the ЧИМЭЭГҮЙ switch located on the front of the alarm enclosure. The horn will cease, but the red alarm beacon will remain illuminated. This visual indicator will stay on until the liquid level returns to normal, signifying that the condition has been remedied.

5.3. Automatic Reset

Once the liquid level drops below the float switch activation point, the system will automatically reset. The red alarm beacon will turn off, and the system will be ready to detect future high-level conditions.

5.4. Дохиоллыг турших

It is recommended to periodically test the alarm system to ensure proper functionality. Press the ТУРШИЛТ switch on the front of the enclosure. This will simulate an alarm condition, activating both the horn and the beacon. Release the switch to return to normal operation.

6. Засвар үйлчилгээ

Regular maintenance helps ensure the longevity and reliability of your Tank Alert XT system.

Жич: Always disconnect power to the alarm unit before performing any maintenance or inspection inside the enclosure.

7. Алдаа засах

If your Tank Alert XT system is not functioning as expected, refer to the following common issues and solutions:

АсуудалБоломжит шалтгаанШийдэл
Alarm not sounding/beacon not lighting up during high level or test.Төхөөрөмжид цахилгаан байхгүй байна.
Буруу хөвөх унтраалга.
Сул утас холболт.
Гэмтсэн дохиоллын төхөөрөмж.
Цахилгаан хангамж ба таслуурыг шалгана уу.
Verify float switch operation by manually raising it.
Inspect all wiring connections inside the enclosure.
Contact SJE-Rhombus support if unit is damaged.
Сэрүүлэг тасралтгүй дуугарна.Liquid level remains high.
Float switch stuck in activated position.
Faulty float switch or wiring.
Address the high liquid level condition.
Inspect float switch for obstructions or debris; clean if necessary.
Check float switch and wiring for damage.
Alarm horn silenced, but beacon remains off.Faulty alarm beacon.
Дотоод утастай холбоотой асуудал.
Contact SJE-Rhombus support for repair or replacement.
Alarm does not auto-reset.Liquid level still high.
Float switch stuck or damaged.
Ensure liquid level has dropped below activation point.
Inspect and clean float switch; ensure free movement. Replace if damaged.

If troubleshooting steps do not resolve the issue, please contact SJE-Rhombus customer support.

8. Баталгаат хугацаа ба дэмжлэг

SJE-Rhombus products are manufactured to high standards and are typically backed by a manufacturer's warranty. Specific warranty terms and conditions, including duration and coverage, are usually provided with the product packaging or can be found on the official SJE-Rhombus webсайт.

For technical assistance, warranty claims, or to purchase replacement parts, please contact SJE-Rhombus customer support directly. Have your product model number (1005481) and date of purchase available when contacting support.

SJE-Rhombus Official Webсайт: www.sjerhombus.com

Please note that product specifications and features are subject to change without notice. Always refer to the latest documentation provided by the manufacturer.