This manual provides essential instructions for the safe and efficient use of your Techly Professional 023189 Vertical Rack Power Strip. Please read this manual thoroughly before installation and operation, and retain it for future reference.
The Techly Professional 023189 is a 12-outlet vertical rack-mountable power distribution unit (PDU) designed for professional environments. It features Schuko outlets, a thermal-magnetic circuit breaker for overload protection, and a durable aluminum and black finish.
Аюулгүй байдлын мэдээлэл
WARNING: To reduce the risk of electric shock, fire, or injury, always follow basic safety precautions when using electrical products.
- Do not exceed the maximum load capacity of 3.5 kW (16 A, 250 V AC).
- Энэ бүтээгдэхүүн нь зөвхөн дотор ашиглах зориулалттай.
- Do not connect multiple power strips together.
- Цахилгааны туузыг зөв газардуулсан эсэхийг шалгаарай.
- Do not open or modify the device. Refer all servicing to qualified personnel.
- Ус, өндөр чийгшил бүхий орчноос хол байлга.
- Ensure proper ventilation when installed in a rack.
Багцын агуулга
Бүх зүйлс байгаа бөгөөд гэмтээгүй эсэхийг шалгана уу:
- Techly Professional 023189 Vertical Rack Power Strip (12 Schuko outlets)
- Хэрэглэгчийн гарын авлага
Image: The product packaging box, labeled "TECHLY PROFESSIONAL 19" Power Distribution Unit".
Бүтээгдэхүүн дууссанview
The Techly Professional 023189 is a robust power distribution unit designed for vertical mounting in 19-inch server racks. It provides 12 Schuko outlets for connecting various electrical devices.
Зураг: Бүрэн view of the Techly Professional 023189 power strip, showing 12 Schuko outlets, the circuit breaker, and mounting brackets.
Гол онцлогууд:
- 12 Schuko (IEC60884) outlets angled at 45°
- Integrated thermal-magnetic circuit breaker for overload protection
- Vertical rack-mountable design
- 3-meter power cable with angled Schuko plug
- Durable aluminum and black finish
- Maximum load capacity: 3.5 kW (16 A, 250 V AC)
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in an open position, revealing the blue switch and "I ON / O OFF" markings.
Зураг: Нарийвчилсан view of the angled Schuko power plug, which connects the power strip to the main power source.
Тохиргоо ба суурилуулалт
- Цахилгаан туузыг задлах: Цахилгааны туузыг савлагаанаас нь болгоомжтой салга. Гэмтлийн шинж тэмдэг байгаа эсэхийг шалгана уу.
- Суулгах байршлыг сонгоно уу: Select a suitable vertical location within a standard 19-inch server rack. Ensure there is adequate space for cable management and ventilation.
- Mount the Power Strip: Use appropriate rack screws (not included) to securely fasten the power strip's mounting brackets to the rack rails.
- Эрчим хүчний эх үүсвэрт холбогдох: Plug the power strip's angled Schuko plug into a properly grounded wall outlet or UPS.
- Төхөөрөмжүүдийг холбох: Plug your electrical devices into the 12 Schuko outlets on the power strip. Ensure the total power consumption does not exceed 3.5 kW.
Зураг: Хэсэгчилсэн view of the power strip, highlighting the mounting brackets on the side, designed for vertical installation in a server rack.
Үйл ажиллагаа
- Асаах: Locate the thermal-magnetic circuit breaker on the power strip. Flip the switch to the "I ON" position to supply power to the outlets.
- Хэт ачааллын хамгаалалт: If the total current drawn by connected devices exceeds 16 A, the thermal-magnetic circuit breaker will automatically trip to the "O OFF" position, cutting power to prevent damage.
- Унтраах: To cut power to all connected devices, flip the circuit breaker switch to the "O OFF" position.
Image: A close-up of the power strip's circuit breaker, showing the transparent protective cover in a closed position, covering the blue switch.
Засвар үйлчилгээ
- Цэвэрлэгээ: Disconnect the power strip from the main power source before cleaning. Use a soft, dry cloth to wipe the exterior. Do not use liquid cleaners or aerosols.
- Шалгалт: Periodically inspect the power strip, cable, and plug for any signs of wear, damage, or overheating. If any damage is observed, discontinue use immediately and replace the unit.
- Агааржуулалт: Ensure that the power strip and connected devices have adequate airflow to prevent overheating.
Алдааг олж засварлах
| Асуудал | Боломжит шалтгаан | Шийдэл |
|---|---|---|
| Гаралтын хэсэгт цахилгаан байхгүй. | Хэлхээ таслагч тасарсан. | Reduce the load by unplugging some devices, then reset the circuit breaker by flipping it to "I ON". |
| Гаралтын хэсэгт цахилгаан байхгүй. | Цахилгаан туузыг залгаагүй байна. | Ensure the power strip's plug is securely inserted into a live wall outlet. |
| Devices not functioning. | Device-specific issue. | Check the individual device's power connection and functionality. |
Хэрэв эдгээр шийдлүүдийг туршиж үзсэний дараа асуудал хэвээр байвал хэрэглэгчийн дэмжлэгтэй холбоо барина уу.
Үзүүлэлтүүд
- Загвар: I-CASE STRIP-12SH
- Брэнд: Techly Professional
- Гаралтын цэгүүд: 12 x Schuko (Type F) 45° angled with earth
- Оролтын залгуур: Angled Schuko (Type F)
- Кабель: H05VV-F 3G 2.5 мм²
- Кабелийн урт: 3 метр
- Цахилгааны үнэлгээ: 16 А, 250 В хувьсах гүйдэл
- Хамгийн их ачааллын багтаамж: 3.5 кВт
- Хэмжээ (L x W x H): 735 x 62 x 44 mm (73.5L x 6.2W cm)
- Жин: 1795 грамм
- Материал: Aluminum (body), Black (finish)
- Онцлог шинж чанар: Mountable (vertical rack installation)
- Баталгаажуулалт: CE, WEEE
Баталгаат хугацааны мэдээлэл
Information regarding specific warranty terms is not available in the provided product details. Please refer to the retailer's return policy or contact Techly Professional directly for warranty details.
Буцаах бодлого: Buybox-ын ялагч нь 30 хоногийн буцаалтын бодлогыг (буцаан олголт/солих) зааж өгнө.
Хэрэглэгчийн дэмжлэг
For technical assistance or further inquiries, please visit the official Techly webсайт эсвэл худалдагчтайгаа холбогдоно уу.
Үйлдвэрлэгч: TECHLY PROFESSIONAL
Webсайт: www.techly.com (Hypothetical link, as not provided in JSON)