Apera Instruments AI1107

Apera Instruments 3M KCL Storage Soaking Solution

Model: AI1107

Брэнд: Apera Instruments

Бүтээгдэхүүн дууссанview

The Apera Instruments 3M KCL Storage Solution is specifically formulated with high-purity chemicals to maintain and extend the operational lifespan of pH and ORP electrodes. This solution is essential for proper electrode care, preventing sensitivity and accuracy degradation that can occur when electrodes are stored dry.

Гол онцлогууд нь:

Тохиргоо ба бэлтгэл

Before storing your pH or ORP electrode, ensure it is thoroughly cleaned according to your electrode's specific cleaning instructions. This removes any contaminants that could affect the electrode's performance or the storage solution's integrity.

Apera Instruments 3M KCL Storage Solution bottle

Зураг: A white plastic bottle containing Apera Instruments 3M KCL Storage Solution. The label on the bottle is primarily in German, indicating "Elektrolyt Lösung" (Electrolyte Solution) and "Kaliumchlorid 3mol/l" (Potassium Chloride 3mol/l), with a volume of "250 ml". The Apera Instruments logo is visible at the top of the label. The bottle has a black ribbed screw cap.

Ашиглалтын заавар

Routine Electrode Storage

To maintain optimal performance and extend the life of your pH or ORP electrode, it is highly recommended to store the electrode in Apera Instruments 3M KCL Storage Solution when not in use. This prevents the electrode's sensitive glass bulb and reference junction from drying out.

  1. Ensure the electrode is clean.
  2. Электродоос хамгаалалтын тагийг ав.
  3. Fill the electrode's storage cap or a small container with a sufficient amount of 3M KCL storage solution to fully immerse the electrode's sensing bulb and reference junction.
  4. Place the electrode into the solution, ensuring the sensing part is completely submerged.
  5. Secure the electrode in the solution to prevent spillage and evaporation.

Restoring Dry or Sluggish Electrodes

If your pH or ORP electrode has been stored dry, or if it exhibits sluggish response or unstable readings, its sensitivity and accuracy may be temporarily compromised. The 3M KCL storage solution can help restore its performance.

  1. Clean the electrode thoroughly.
  2. Immerse the electrode's sensing bulb and reference junction in Apera Instruments 3M KCL Storage Solution.
  3. Allow the electrode to soak in the solution for a minimum of 1 hour, or preferably overnight, to rehydrate the glass membrane and re-establish the reference junction potential.
  4. After soaking, rinse the electrode with distilled water and perform a calibration before use.

Maintenance and Storage of Solution

To ensure the longevity and effectiveness of your Apera Instruments 3M KCL Storage Solution, follow these guidelines:

Алдааг олж засварлах

This section addresses common issues related to electrode performance and how the storage solution can help.

АсуудалБоломжит шалтгаанШийдэл
Electrode shows unstable readings or slow response.Electrode membrane is dry or dehydrated.Soak the electrode in Apera Instruments 3M KCL Storage Solution for at least 1 hour, or overnight. Ensure the sensing bulb is fully submerged.
Electrode requires frequent calibration.Improper storage leading to degradation of electrode performance.Always store the electrode in 3M KCL storage solution when not in use. If performance has degraded, try reconditioning by soaking.
Solution appears cloudy or contaminated.Exposure to contaminants or expired solution.Discard the contaminated or expired solution and replace with fresh Apera Instruments 3M KCL Storage Solution.

Үзүүлэлтүүд

АтрибутДэлгэрэнгүй
Бүтээгдэхүүний нэр3M KCL Storage Soaking Solution
Загварын дугаарAI1107
БрэндApera хэрэгслүүд
Зүйлийн хэмжээ8 шингэн унц (ойролцоогоор 236 мл)
KCL Concentration3M (3 mol/L)
Барааны маягтШингэн
Багцын мэдээлэлЛонх
Бүтээгдэхүүний хэмжээс6.3 x 1.97 x 2.36 инч
Зүйлийн жин9 унц
Гарал үүслийн улсАНУ

Баталгаат хугацааны мэдээлэл

Specific warranty details for the Apera Instruments 3M KCL Storage Soaking Solution are not provided in this manual. For comprehensive warranty information, please refer to the official Apera Instruments webсайт эсвэл тэдний хэрэглэгчийн дэмжлэгтэй шууд холбогдоно уу.

Дэмжлэг ба холбоо барих

For further assistance, technical support, or to download batch certificates for your solution, please visit the official Apera Instruments webсайт:

www.aperainst.com

(Note: The image indicates a German website for certificates: aperainst.de/chargenzertifikate/. Please refer to your region's specific support channels.)

Холбогдох баримт бичиг - AI1107

Урьдчилсанview Apera SX811-SS Хүнсний туршилтын зөөврийн рН хэмжигч: Зааварчилгаа, техникийн үзүүлэлтүүд
Apera SX811-SS зөөврийн рН тоолуурын иж бүрэн зааварчилгааны гарын авлага, техникийн үзүүлэлтүүд нь хүнсний бүтээгдэхүүний үнэн зөв туршилт хийхэд зориулагдсан. Онцлогууд, тохируулга, тохиргоо, USB холболт болон алдааг олж засварлах талаар мэдэж аваарай.
Урьдчилсанview PH60Z-HT Ухаалаг рН тоолуурын хэрэглэгчийн гарын авлага - Apera Instruments
Apera Instruments PH60Z-HT Ухаалаг рН тоолуурын хэрэглэгчийн гарын авлагад түүний онцлог, ажиллагаа, тохируулга, засвар үйлчилгээ, өндөр температур ба идэмхий уусмалын алдааг олж засварлах талаар дэлгэрэнгүй бичсэн болно.
Урьдчилсанview PH60Z-PW Ухаалаг pH-метр Wasser reines Bedienungsanleitung
Umfassende Bedienungsanleitung für das Apera Instruments PH60Z-PW Ухаалаг рН-метр. Erfahren Sie mehr über Kalibrierung, Messung, Wartung und technische Daten für präzise pH-Messungen in reinem Wasser.
Урьдчилсанview Apera PH700 ширээний рН хэмжигч хэрэгслийн зааварчилгааны гарын авлага
Apera PH700 ширээний рН хэмжигчийг ажиллуулах, тохируулах, засвар үйлчилгээ хийх цогц зааварчилгаа. Үүнд техникийн үзүүлэлтүүд, багажийн тодорхойлолт, рН болон ORP-ийн хэмжилтийн журам, параметрийн тохиргоо, электродын арчилгаа, алдааг олж засварлах зэрэг орно.
Урьдчилсанview Apera Instruments SX731 Portable pH/Conductivity/ORP Meter User Manual
User manual for the Apera Instruments SX731 Portable pH/Conductivity/ORP Meter, covering its features, technical specifications, operation, calibration, maintenance, and warranty.
Урьдчилсанview APERA Instruments pH 4.00 Буферийн уусмалын аюулгүй байдлын мэдээллийн хуудас
APERA Instruments pH 4.00 буфер уусмалын аюулгүй байдлын мэдээллийн хуудас (SDS) нь таних тэмдэг, аюул, анхны тусламж, харьцах, хадгалах, зохицуулалтын нийцлийн талаарх чухал мэдээллийг агуулдаг.