The Cartell CP-4 Smart Driveway Free Exit Wand Sensor System is designed to provide a reliable and convenient solution for automatic gate openers, allowing vehicles to exit a property without requiring a remote or keypad. This self-contained system is a direct replacement for the CP-3 model, offering enhanced features and improved performance.

Гол онцлогууд:

  • Direct replacement for CP-3 with added features.
  • Self-contained system for easy integration.
  • Connects directly to any gate opener system without an external output board.
  • Compatible with solar-powered gates.
  • Conduit-ready housing for protected installation.
  • Adjustable sensitivity for optimal performance.
  • Improved heat resistance and lightning protection.
  • New proven digital circuit for reliable operation.
  • Weather-resistant cable with industry-standard wire colors.
  • Бүх нийтийн ботьtage AC & DC compatibility.
  • Works with all gate operators.

Бүтээгдэхүүн дууссанview

The Cartell CP-4 system consists of a sensor unit (often referred to as a 'puck') with an integrated cable, designed for burial to detect the presence of vehicles.

Бүрэлдэхүүн хэсгүүд:

  • CP-4 Sensor Unit (Puck)
  • Integrated 100-foot Cable
Cartell CP-4 Smart Driveway Free Exit Wand Sensor System with 100-foot cable

Image: The Cartell CP-4 sensor unit, a black rectangular device, with its coiled 100-foot cable. The cable has multiple colored wires at its end for connection.

Суурилуулалт

Proper installation is crucial for the optimal performance and longevity of your Cartell CP-4 system. It is highly recommended to run the cable in conduit to protect it and facilitate future maintenance or replacement.

Installation instructions for Cartell CP-4

Image: A diagram illustrating the installation steps for the Cartell CP-4, including serial number location, trenching, conduit use, wiring connections, sensitivity adjustment, and burial depth.

Алхам алхмаар суурилуулах:

  1. 1. Серийн дугаар

    Locate the serial number on the bottom of the 'puck' unit and on the product box. This number is handy for product inquiries and support.

  2. 2. Trenching Pipe & Cable

    Trench 1/2" PVC pipe beside the driveway where the CP-4 will be buried. The trench should be deep enough to allow for 3-5 inches of cover over the buried unit. Note: Warranty may be voided if the cable is not run in conduit.

  3. 3. Conduit & Slip Joint

    After pulling the cable through the plastic conduit, insert the conduit inside the slip joint on the 'puck'. Do NOT glue the slip joint to allow for easy un-installation if needed.

  4. 4. Connect to Gate

    The CP-4 works with all gate operators (powered or solar). Connect wires as follows:

    Утасны өнгөFunction (Power Gates)Function (Solar Gates)
    УлаанЭрчим хүч +Эрчим хүч +
    ХарCommon -Ground or Common
    ЦагаанExit N.O.Free Exit or Open Terminal
    ЦэнхэрExit N.C.Үгүй
    ШарExit N.C.Үгүй

    The system supports universal voltage AC & DC (8-24 VAC or 8-30 VDC).

  5. 5. Test Sensitivity

    In most cases, sensitivity will NOT need to be adjusted as it is set to high from the factory. However, if adjustment is needed, use the DIP switches inside the unit:

    • ӨНДӨР (Өгөгдмөл): Detects vehicles 12-14 feet. DIP switches 1 & 2 are in OFF position.
    • ДУНД: Detects vehicles 5-6 feet. DIP switch 1 is ON, 2 is OFF.
    • БАГА: Detects vehicles 2-3 feet. DIP switch 1 is OFF, 2 is ON.

    Note: DIP switch color may vary.

  6. 6. Bury Conduit & "Puck"

    Test the unit with the gate by driving a steel vehicle over the 'puck' (or driving vehicle by). If it opens the gate correctly, finish installation by burying the conduit and 'puck' 3-5 inches below the surface.

Other Installation Considerations:

  • The CP-4 may be installed above ground by screwing the 'puck' directly to a post or building. If above ground, ensure the puck is immovable to eliminate false alarms.
  • If installed above ground, conduit is required to mechanically protect the cable (animals will eat it).
  • Хамгийн багадаа CP-4 суулгана уу:
    • 6-10 feet away from buried power, telephone, or invisible dog fence.
    • 10 feet away from natural gas lines.
    • 20 feet away from power pole with a transformer.
    • 100 feet back from railroad traffic.
    • 200 feet away from high power substation power lines.
    • 80-100 feet back from gate operator.

Үйл ажиллагаа

The Cartell CP-4 system operates by detecting magnetic disturbances caused by moving steel vehicles. When a vehicle passes the sensor, a signal is sent to your gate operator, triggering the gate to open for free exit.

Car approaching a closed gate

Image: A black SUV approaching a closed ornate metal gate with stone pillars, illustrating the scenario where the sensor would activate.

Car passing through an open gate

Image: The same black SUV passing through the now open ornate metal gate, demonstrating the system's function.

Систем хэрхэн ажилладаг вэ:

Diagram showing a car entering or leaving a driveway

Image: A diagram with the number '1' indicating 'A Car Enters or Leaves a Driveway'. Our vehicle detection systems sense magnetic disturbance when a vehicle passes the sensor traveling at least five MPH.

Diagram showing a signal being sent

Image: A diagram with the number '2' indicating 'A Signal is Sent'. Once a car is detected, an activity notification is sent either wirelessly or through wires to an existing security/home automation system, a Cartell control unit, or to a gate operator for free exit.

Diagram showing alerts being activated

Image: A diagram with the number '3' indicating 'Alerts are Activated'. Cartell systems can activate audible alerts, trigger cameras and lights, integrate with components of a security/home automation system, or automatically open a driveway gate for free exit.

Diagram indicating no false alarms

Image: A diagram with an icon of a deer and leaves, indicating 'No False Alarms'. No person, animal, or blowing leaf will trigger our system. We only detect moving steel. If your Cartell system is activated, you can be sure there's a vehicle in your driveway.

Diagram indicating reliable alerts

Image: A diagram with a bell icon, indicating 'Reliable Alerts'. Whether you're using your system to send a signal to your smart home, turn on lights, activate alarms, or open your gate for free exit, you can trust your property to Cartell.

Засвар үйлчилгээ

The Cartell CP-4 system is designed for minimal maintenance. However, periodic checks can ensure continued reliable operation:

  • Кабелийг шалгах: Periodically check the exposed portions of the cable for any signs of damage, especially if not run through conduit.
  • Цэвэрлэх талбай: Ensure the area directly above the buried sensor is clear of large metal objects or debris that could interfere with detection.
  • Холболтын бүрэн бүтэн байдал: Verify that all wire connections to the gate operator are secure and free from corrosion.
  • Conduit Protection: If the unit needs replacement in the future, having the cable run through conduit will significantly simplify the process, as you can often fish a new wire through the existing conduit without re-trenching.

Алдааг олж засварлах

If you encounter issues with your Cartell CP-4 system, consider the following common problems and solutions:

  • System Not Detecting Vehicles:
    • Check the sensitivity setting (DIP switches). It might be set too low for your vehicle type or installation depth.
    • Verify that the vehicle is made of steel and is moving at least 5 MPH when passing the sensor.
    • Ensure the sensor is buried at the correct depth (3-5 inches).
    • Inspect the cable for any damage or breaks, especially if not in conduit.
  • Gate Not Opening After Detection:
    • Confirm all wiring connections to the gate operator are correct and secure (Red, Black, White, Blue/Yellow).
    • Check the power supply to the CP-4 unit (8-24 VAC or 8-30 VDC).
    • Ensure the gate operator itself is functioning correctly and is receiving the signal from the CP-4.
  • Хуурамч өдөөгч хүчин зүйлс:
    • Adjust the sensitivity setting to a lower level.
    • Ensure there are no large, moving metal objects (e.g., metal trash cans, tools) near the sensor's detection zone.
    • Verify the sensor is installed at the recommended distances from power lines, transformers, and other potential interference sources.
  • Unit Failure (e.g., due to moisture):
    • While the unit is designed to be weather-resistant, ensure proper sealing and installation, especially if not using conduit.
    • If you suspect internal damage or moisture ingress, contact Cartell customer support for assistance. They may require detailed meter readings for diagnosis.

Техникийн үзүүлэлтүүд

Technical specifications and other instructions for Cartell CP-4

Image: A document detailing other installation instructions, technical specifications, and return merchandise information for the Cartell CP-4.

ТодорхойлолтҮнэ цэнэ
Шаардлагатай эрчим хүч8-24 VAC эсвэл 8-30 VDC
Стэнд-бай гүйдэл30-70 бичилampс (μA)
Сэрүүлгийн гүйдэл30-40 саяampс (мА)
Релений цаг2-3 секунд
Реле харилцагчидSPDT, Floating, N.O. or N.C. (Form C)
Реле контактын үнэлгээ1 amp/24 VDC (1 VDC мин. ачаалалтай үед 5 мА)
Хавсралтын үнэлгээIP67
Хүч чадлын үнэлгээ9.53 lbf-force, 8646 kgf
Температурын хүрээ-25°F - +140°F (-32°C - 60°C)
Хэмжээ4.5 in. Dia. x 2.5 in. high
Жин4.4 pounds (with 100 ft. cable)
ҮйлдвэрлэгчCARTELL
Барааны багцын тоо1
Батерей багтсан уу?Үгүй
Батерей шаардлагатай юу?Үгүй
Эхний боломжтой огноо31 оны аравдугаар сарын 2019

Баталгаат болон дэмжлэг

Warranty and contact information for Cartell

Image: A document detailing the 5-year warranty, return merchandise instructions, and various contact information for Cartell.

5 жилийн баталгаа:

All Cartell products are warranted against defects in material and workmanship for five years. This warranty does not cover defects caused by, but not limited to: acts of God, improper installation, abuse, fire damage, electrical surges, and damage to cable caused by slicing, pulling, tangling, improper splicing or not running in non-metallic conduit.

Returning Merchandise:

Хэрэглэгч: Суулгагчтайгаа холбогдоно уу.

Суулгагч: Call BEFORE DIGGING UP. Call (717) 532-0033, option 1 to troubleshoot and receive a Return Merchandise Authorization (R.M.A.) number. Write the R.M.A. number on the return shipping box and any correspondence included with the defective product.

Түгээгч: Send installers directly to Cartell, using (717) 532-0033, option 1 as the phone number.

Холбоо барих мэдээлэл:

хэлтэсХолбоо барих мэдээлэл
Техникийн дэмжлэг717-532-0033, сонголт 1
RMA's717-532-0033, сонголт 1
Хүргэлт717-532-0033, сонголт 2
Нягтлан бодох бүртгэл717-532-0033, сонголт 3
Имэйлinfo@cartell.com
Ordering (Distributors only)orders@cartell.com
Хаяг510 Баруун Кинг гудамж, Шиппенсбург, ТХГН-ийн 17257
Webсайтwww.cartell.com

Холбогдох баримт бичиг - CP-4

Урьдчилсанview Cartell CP-4 Automatic Gate Opener Installation Guide
Comprehensive installation instructions for the Cartell CP-4 Automatic Gate Opener. This guide covers serial number identification, gate connection wiring, trenching and cable setup, sensitivity testing, burying procedures, technical specifications, warranty information, and contact details.
Урьдчилсанview Cartell CP-4 Automatic Gate Opener Installation Instructions
Comprehensive installation guide for the Cartell CP-4 Automatic Gate Opener, covering setup, wiring, sensitivity testing, and technical specifications. This document provides step-by-step instructions for installing the CP-4 vehicle detector for gate automation.
Урьдчилсанview Cartell CW-SYS хос зориулалттай утасгүй замын системийг суурилуулах, ашиглах гарын авлага
Cartell CW-SYS Dual-Porpose Wireless Driveway System-ийг суулгах, хослуулах, ажиллуулах дэлгэрэнгүй гарын авлага. Техникийн үзүүлэлтүүд, алдааг олж засварлах зөвлөмжүүд, баталгаат мэдээллийг багтаасан болно.
Урьдчилсанview Cartell GateMate CP-3 Professional Free Exit and Home Automation System Installation and Operation Manual
Comprehensive installation and operation manual for the Cartell GateMate CP-3, a professional electronic vehicle detection device designed for free exit and home automation. Details three-wire and five-wire models, installation procedures, wiring diagrams, testing methods, and technical specifications.
Урьдчилсанview Cartell CW-CON DIY Wireless Driveway System суурилуулах гарын авлага
Энэхүү гарын авлагад Cartell CW-CON DIY Wireless Driveway System-ийг суулгах, ажиллуулах дэлгэрэнгүй зааврыг өгдөг. Энэ нь хайрцгийг задлах, мэдрэгч, дуу авианы тохируулга, хослуулах, турших, мэдрэмжийн тохируулга, техникийн үзүүлэлтүүд, алдааг олж засварлах, баталгаат мэдээллийг багтаасан болно.
Урьдчилсанview Cartell CW-SYS хос зориулалттай утасгүй замын системийг суурилуулах, ашиглах гарын авлага
Comprehensive guide to installing and operating the Cartell CW-SYS Dual-Purpose Wireless Driveway System, detailing setup, pairing, testing, sensitivity settings, installation methods, integration, and troubleshooting.