This manual provides detailed instructions for the Waveshare Industrial Modbus RTU 8-Channel Relay Module. This module is designed for industrial control applications, offering reliable relay switching via an RS485 interface using the Modbus RTU protocol. It features multiple isolation protection circuits for enhanced safety and stability.

Гол онцлогууд нь:

  • Configurable device address (1-255) for multi-device cascading on an RS485 bus.
  • Flash-on, flash-off function for timed relay activation.
  • Onboard unibody power supply isolation for stable isolated voltage.
  • Onboard unibody magnetic isolation for signal integrity, high reliability, and strong anti-interference.
  • Onboard TVS (Transient Voltage Suppressor) for surge and transient spike voltage suppression, providing lightning protection and anti-electrostatic capabilities.
  • Onboard optocoupler isolation to prevent interference from external high-voltage хэлхээнүүд.
  • Reverse-proof circuit to protect against accidental damage from incorrect power connection.
  • High-quality relays with a contact rating of ≤10A 250VAC/30VDC.
  • Rail-mounted ABS plastic enclosure for easy installation and safe use.
  • Three LEDs indicating MCU status and signal transceiving status.

2. Багцын агуулга

The standard package for the Waveshare Industrial Modbus RTU 8-Channel Relay Module includes the following items:

  • Waveshare Modbus RTU 8-Channel Relay Module
  • Power adapter (may vary by region)
Package contents of the Waveshare Modbus RTU 8-Channel Relay Module

Image 2.1: The image displays the Waveshare Modbus RTU 8-Channel Relay Module along with a power adapter and a USB to RS485 converter (converter not included with the module).

3. Техник хангамж дууссанview

The Modbus RTU 8-Channel Relay Module is designed with robust components and protection circuits. Understanding its internal structure is crucial for proper use and troubleshooting.

Internal hardware analysis of the Waveshare Modbus RTU 8-Channel Relay Module

Image 3.1: This image provides a detailed view of the module's internal components, highlighting the high-quality relays, optocoupler isolation, magnetic signal isolation, power supply isolation, TVS lightning & ESD protection, and thickened tracks for large current.

3.1. Гол бүрэлдэхүүн хэсгүүд

  • High Quality Relay: Ensures reliable switching for connected devices.
  • Optocoupler Isolation: Provides electrical isolation between control and load circuits.
  • Magnetic Signal Isolation: Enhances signal integrity and anti-interference capabilities.
  • Power Supply Isolation: Isolates the power supply for stability and safety.
  • TVS Lightning & ESD Protection: Vol-ээс хамгаалдагtage surges and electrostatic discharge.
  • Thickened Track for Large Current: Designed to handle higher current loads safely.

3.2. Enclosure Design

The module is housed in a rail-mounted ABS plastic enclosure, facilitating easy installation in industrial environments and ensuring safe operation.

Rail-mounted ABS plastic enclosure design of the relay module

Image 3.2: The image shows the module's rail-mounted ABS plastic enclosure, designed for easy and secure installation.

4. Тохиргоо

Follow these steps to set up your Waveshare Industrial Modbus RTU 8-Channel Relay Module.

4.1. Эрчим хүчний холболт

  1. Connect the provided power adapter to the DC 5V input terminal of the relay module. Ensure the polarity is correct to prevent damage.
  2. Verify that the power LED indicator on the module illuminates, indicating successful power-on.

4.2. RS485 Communication Setup

The module communicates via RS485. Multiple devices can be cascaded on the RS485 bus. If communication distance is long, RS485 repeaters may be necessary.

  1. Connect the RS485 A+, B-, and GND terminals of the module to your RS485 master device (e.g., a computer with a USB to RS485 converter, or a PLC).
  2. Ensure correct wiring: A+ to A+, B- to B-, and GND to GND.
  3. For multiple modules, connect them in a daisy-chain configuration as shown in the diagram below.
RS485 communication wiring diagram for multiple relay modules

Image 4.1: This diagram illustrates how to connect multiple Modbus RTU relay modules in a daisy-chain configuration using an RS485 bus, typically connected to a USB to RS485 converter.

4.3. Device Address Configuration

Each module on the RS485 bus must have a unique device address, configurable from 1 to 255. Refer to the Modbus RTU protocol documentation for your specific software or controller to set the device address.

5. Ашиглалтын заавар

The Waveshare Modbus RTU 8-Channel Relay Module operates using the standard Modbus RTU protocol over an RS485 interface. This section outlines how to control the relays.

5.1. Modbus RTU Protocol

The module responds to standard Modbus RTU commands. You will typically use Modbus function codes to read coil status, write single coils, or write multiple coils to control the relays. Consult the Modbus RTU specification for detailed command structures.

5.2. Relay Control

Each of the 8 channels corresponds to a relay. Relays can be individually controlled (turned ON/OFF) using Modbus commands. The module also supports a flash-on, flash-off function, allowing you to activate a relay for a specified duration and then automatically deactivate it.

5.3. LED үзүүлэлтүүд

  • STA (Статус) LED: Keeps flashing when the MCU is working normally.
  • TXD (Transmit) LED: Lights up when the module is sending data.
  • RXD (Receive) LED: Lights up when the module is receiving data.

6. Relay Connection

The module's relays have a contact rating of ≤10A 250VAC/30VDC. This allows direct control of various AC and DC devices. Always ensure that the connected load does not exceed the relay's maximum current and voltage үнэлгээ.

6.1. AC 220V Device Connection

For connecting AC 220V devices, ensure proper insulation and safety precautions. Connect the AC load to the COM (Common) and NO (Normally Open) terminals of the desired relay channel.

6.2. DC 30V Device Connection

For connecting DC devices up to 30V, connect the DC load to the COM (Common) and NO (Normally Open) terminals of the desired relay channel. Ensure correct polarity for DC loads.

Relay connection diagrams for AC 220V and DC 30V devices

Image 6.1: This diagram illustrates how to connect both AC 220V and DC 30V devices to the relay module. It shows wiring for a light bulb (AC) and a motor (DC) using the COM and NO terminals, with the module powered by DC 5V.

7. Хэрэглээ

The Waveshare Industrial Modbus RTU 8-Channel Relay Module is versatile and suitable for a wide range of applications:

  • Аж үйлдвэрийн хяналт: Valve control, pump station control, and unattended industrial control systems.
  • Ухаалаг гэр: Controlling appliances like air conditioners, access control systems, purifiers, and water heaters.
  • Intelligent Agriculture: Controlling door curtain motors, air blowers, and other agricultural equipment.
  • Breeding & Farming: Controlling ventilators, lighting, water supply systems, and feeding systems.
Various application scenarios for the relay module

Image 7.1: This image displays four common application areas for the relay module: Industrial Control, Smart Home, Intelligent Agriculture, and Breeding & Farming, showing examples of equipment that can be controlled.

8. Техникийн үзүүлэлтүүд

Detailed technical specifications for the Modbus RTU Relay Module:

ОнцлогModbus RTU RelayModbus RTU Relay (B)
Эрчим хүчний хангамж5V7-36 В
Харилцаа холбооны интерфейсRS485
Дохионы түвшин4800, 9600, 19200, 38400, 57600, 115200, 128000, 256000
Default Communication Format9600, N, 8, 1
Релей сувгууд8
Холбоо барих маягт1NO 1NC
Холбоо барих үнэлгээ≤10A 250VAC/30VDC
Харилцааны протоколStandard Modbus RTU protocol
RS485 хаяг1-255
LED үзүүлэлтүүдSTA: MCU indicator, keeps flashing when the MCU normally working
TXD: TX indicator, lights up when sending data
RXD: RX indicator, lights up when receiving data

9. Засвар үйлчилгээ

The Waveshare Industrial Modbus RTU 8-Channel Relay Module is designed for robust and reliable operation with minimal maintenance. To ensure longevity and optimal performance:

  • Цэвэр байлгах: Periodically clean the exterior of the module with a soft, dry cloth. Avoid using harsh chemicals or abrasive materials.
  • Байгаль орчны нөхцөл: Operate the module within its specified temperature and humidity ranges. Avoid exposure to excessive dust, moisture, or corrosive environments.
  • Холболтын бүрэн бүтэн байдал: Regularly check all wiring connections (power, RS485, and relay loads) to ensure they are secure and free from corrosion or damage.
  • Програм хангамжийн шинэчлэлтүүд: Check the official Waveshare website for any available firmware updates that may improve performance or address issues. Follow update instructions carefully.

10. Алдаа засах

If you encounter issues with your Waveshare Industrial Modbus RTU 8-Channel Relay Module, refer to the following troubleshooting tips:

  • Модуль асахгүй байна:
    • Ensure the power adapter is correctly connected and providing the specified voltage (5V for this model).
    • Check the power outlet and cable for functionality.
    • Verify the power LED indicator. If it's off, there might be a power issue.
  • No RS485 Communication:
    • Verify RS485 wiring: A+ to A+, B- to B-, and GND to GND.
    • Check the baud rate, data bits, parity, and stop bits settings in your Modbus master software. These must match the module's default or configured settings (e.g., 9600, N, 8, 1).
    • Ensure the module's RS485 device address is unique and correctly configured in your master software.
    • Observe the TXD and RXD LEDs. If they are not flashing during communication attempts, check wiring and software settings.
    • For long distances or multiple devices, consider adding RS485 terminators or repeaters.
  • Relays Not Activating:
    • Confirm that the module is powered on and communicating correctly (check communication LEDs).
    • Verify the Modbus commands sent to activate the specific relay channels.
    • Check the wiring of the load connected to the relay. Ensure the load's power supply is active and within the relay's contact rating.
    • Ensure the load itself is functional.
  • Завсарлагатай ажиллагаа:
    • Check for loose connections on power, RS485, and relay terminals.
    • Ensure the operating environment is stable and free from excessive electrical noise or temperature fluctuations.
    • Verify that the power supply is stable and sufficient for both the module and the connected loads.

11. Тойм хэмжээсүүд

The physical dimensions of the Waveshare Industrial Modbus RTU 8-Channel Relay Module are provided below for installation planning.

Outline dimensions of the Waveshare Modbus RTU 8-Channel Relay Module

Image 11.1: This image provides detailed measurements of the module, including its length (145mm), width (90mm), and height (40mm), along with other specific dimensions for mounting.

12. Баталгаат хугацаа ба дэмжлэг

Waveshare products are designed for quality and reliability. For specific warranty information, please refer to the warranty policy provided with your purchase or visit the official Waveshare website. For technical support, documentation, and additional resources, please visit the Waveshare support portal or contact their customer service directly.

Албан ёсны Waveshare Webсайт: www.waveshare.com

Холбогдох баримт бичиг - Modbus RTU Relay

Урьдчилсанview Modbus RTU Relay: User Manual and Technical Guide
Comprehensive guide to the Modbus RTU Relay, covering safety instructions, hardware connection, software setup with SSCOM and Modbus Poll, and detailed command protocols for various operations. Includes examples for Raspberry Pi, STM32, Arduino, and PLC integration.
Урьдчилсанview Modbus RTU Relay 32CH User Manual and Technical Guide
Comprehensive user manual and technical guide for the Modbus RTU Relay 32CH. Covers safety, hardware, software integration (Raspberry Pi, STM32, Arduino, PLC), and Modbus RTU command protocols for industrial automation.
Урьдчилсанview Waveshare Modbus POE ETH Relay 30CH: User Manual and Configuration Guide
This document provides a comprehensive guide to the Waveshare Modbus POE ETH Relay 30CH. It covers product overview, hardware connection, electrical safety precautions, detailed specifications, indicator descriptions, configuration methods using VirCom software and web interface, protocol settings (Modbus RTU/TCP), virtual serial port setup, software demonstrations with SSCOM and Modbus Poll, Raspberry Pi integration, and Modbus development protocols. Learn how to control and monitor industrial automation devices.
Урьдчилсанview Module d'Entrée Analogique Modbus RTU 8 Canaux par Waveshare
Ce document technique présente le module d'entrée analogique 8 canaux Modbus RTU de Waveshare, conçu pour l'acquisition de données de tension et de courant dans les systèmes d'automatisation industrielle. Il détaille les spécifications techniques, les méthodes de connexion, les tests logiciels et le protocole de communication Modbus.
Урьдчилсанview Modbus POE ETH Relay User Manual and Configuration Guide
Comprehensive guide for the Waveshare Modbus POE ETH Relay, covering hardware connection, safety instructions, parameter configuration using Vircom software and web interface, virtual serial port setup, and detailed Modbus RTU/TCP protocol commands and examples.
Урьдчилсанview Modbus RTU E/S 8CH: Industrial 8-Channel Digital Input/Output Module
Comprehensive technical guide for the Waveshare Modbus RTU E/S 8CH module, detailing its specifications, wiring, primary functions, testing procedures, and Modbus communication protocol for industrial automation applications.