ACEMIC ST-5

ACEMIC ST-5 Wireless Microphone System User Manual

Загвар: ST-5

Танилцуулга

The ACEMIC ST-5 is a portable digital wireless microphone system designed for instruments such as saxophones, suitable for stage performances and street performances. It features digital wireless audio transmission, 16 selectable frequencies, and a digital ID code to prevent interference. This manual provides instructions for the proper setup, operation, and maintenance of your ST-5 system.

Тохируулах гарын авлага

1. Багцын агуулга

Before proceeding, please ensure all components are present:

  • 1 x ACEMIC ST-5 Wireless Receiver
  • 1 x ACEMIC ST-5 Wireless Transmitter with Microphone
  • 1 x Lithium Battery (for each unit)
  • 1 x Charging Cable (not explicitly listed but implied for lithium battery)
ACEMIC ST-5 Wireless Microphone System components

Image: The ACEMIC ST-5 wireless microphone system, showing both the receiver unit and the clip-on microphone transmitter.

2. Анхны цэнэглэлт

Both the receiver and transmitter are powered by 3.7V lithium batteries. For optimal performance, fully charge both units before first use.

  • Connect the charging cable to the charging port on each unit.
  • Connect the other end of the charging cable to a suitable USB power source (e.g., computer USB port, USB wall adapter).
  • Цэнэглэх үед цэнэглэх заагч гэрэл нь ихэвчлэн улаан өнгөтэй байх бөгөөд бүрэн цэнэглэгдсэн үед унтрах эсвэл өнгөө өөрчлөх болно.

3. Хүлээн авагчийг холбох

The receiver features a 6.35mm plug for direct connection to a mixer or active speaker.

  • Ensure your mixer or active speaker is powered off before connecting the receiver.
  • Insert the 6.35mm plug of the receiver into an available 6.35mm input jack on your audio device.
  • Power on your mixer or active speaker after the receiver is securely connected.
ACEMIC ST-5 Wireless Receiver

Image: The ACEMIC ST-5 wireless receiver unit, showing the 6.35mm plug and branding.

4. Attaching the Microphone Transmitter

The microphone transmitter is designed to clip onto instruments like a saxophone.

  • Carefully open the clip on the transmitter unit.
  • Attach the clip securely to the bell or another suitable part of your instrument, ensuring the microphone capsule is positioned to capture sound effectively without obstructing play.
  • Adjust the flexible gooseneck of the microphone to achieve the desired proximity and angle to the sound source.
ACEMIC ST-5 Microphone Transmitter

Image: The ACEMIC ST-5 microphone transmitter with its clip and flexible gooseneck.

ACEMIC ST-5 Microphone attached to a saxophone

Image: The ACEMIC ST-5 microphone transmitter clipped onto a saxophone, demonstrating typical placement.

5. Pairing and Frequency Synchronization

The system uses IR sync for frequency downloading and a digital ID code to prevent interference.

  • Power on both the receiver and the transmitter.
  • Locate the IR sensor on both units.
  • Align the IR sensors of the receiver and transmitter within close proximity (e.g., 1-2 cm).
  • Initiate the synchronization process (refer to the specific button or sequence on your device, often labeled 'SYNC' or similar). The units will automatically download and match frequencies.
  • Once synchronized, the RF indicator on the receiver should illuminate, indicating a successful connection.

Ашиглалтын заавар

1. Асаах/унтраах

  • To power on: Press and hold the power button on both the receiver and transmitter until the indicator lights illuminate.
  • To power off: Press and hold the power button on both units until the indicator lights turn off.

2. Дууны хэмжээг тохируулах

Volume adjustments should primarily be made on your connected mixer or active speaker. Ensure the input gain on your audio device is set appropriately to avoid distortion.

3. Үйл ажиллагааны хүрээ

The ACEMIC ST-5 system offers an operating range of up to 40 meters (line-of-sight). Obstacles such as walls, large metal objects, or other wireless devices can reduce this range. Maintain a clear line of sight between the transmitter and receiver for optimal performance.

Засвар үйлчилгээ

1. Зайны арчилгаа

  • Recharge the lithium batteries when the low battery indicator appears or when performance degrades.
  • Avoid completely draining the batteries regularly, as this can shorten their lifespan.
  • If storing the unit for an extended period, charge the batteries to approximately 50% and store in a cool, dry place. Recharge every few months to prevent deep discharge.

2. Цэвэрлэгээ

  • Use a soft, dry cloth to clean the exterior of the receiver and transmitter.
  • For the microphone foam windscreen, gently remove and clean with mild soap and water if necessary, ensuring it is completely dry before reattaching.
  • Avoid using harsh chemicals, solvents, or abrasive materials, as these can damage the finish or internal components.

Алдааг олж засварлах

If you encounter issues with your ACEMIC ST-5 system, please refer to the following common solutions:

  • Дууны гаралт байхгүй:
    • Ensure both the receiver and transmitter are powered on and fully charged.
    • Verify that the receiver is securely plugged into the mixer/speaker and that the audio device's input is active and volume is up.
    • Check if the receiver and transmitter are properly synchronized (RF indicator on receiver should be lit). If not, re-sync them.
    • Confirm that the microphone is positioned correctly and not muted (if a mute function is present).
  • Хөндлөнгийн оролцоо эсвэл дууны чанар муу:
    • Ensure there are no other strong wireless signals operating on similar frequencies nearby.
    • Re-synchronize the units to potentially select a clearer frequency. The system has 16 selectable frequencies.
    • Maintain a clear line of sight between the transmitter and receiver. Avoid placing units near large metal objects or other electronic devices that may cause interference.
    • Check the battery levels; low battery can affect signal strength.
  • Богино хугацааны үйл ажиллагааны хүрээ:
    • Ensure there is a clear line of sight between the transmitter and receiver.
    • Check battery levels on both units.
    • Avoid environments with excessive wireless interference.

Үзүүлэлтүүд

ОнцлогДэлгэрэнгүй
Digital Wireless Audio TransmissionТиймээ
Аудио С.ampling горим48 кГц
Pre-set Selectable Frequencies16
Digital ID CodeYes (solves frequency interference)
IR синхрончлолYes (for frequency downloading)
Үйл ажиллагааны хүрээUp to 40m (line-of-sight)
ТохиромжтойSaxophone stage performances, street performances, etc.
Хүлээн авагчийн гаралт6.35 мм залгуур
Эрчим хүчний хангамж3.7V Lithium battery (for both units)
Receiver Latency<6 мс
Давтамжийн хариу үйлдэл60Hz - 15KHz ± 2dB
Нийт гармоник гажуудал<0.8% (1KHz)
Дохио/дуу чимээний харьцаа>92дБ
Хүлээн авах мэдрэмж-92 дБм
Дамжуулагчийн хүч10мВт
Микрофоны мэдрэмж-47 дБ ± 2 дБ
Микрофоны төрөлКонденсатор
Зайны амьдрал (тасралтгүй ашиглах)>6 цаг
Зүйлийн жин1.21 фунт
UPC712350112585

Баталгаат болон дэмжлэг

For warranty information, technical support, or service inquiries regarding your ACEMIC ST-5 Wireless Microphone System, please contact ACEMIC customer service through their official webсайт эсвэл та бүтээгдэхүүнийг худалдаж авсан жижиглэн худалдаачин. Баталгаат хугацааны нэхэмжлэлийн хувьд худалдан авалтын баримтаа хадгална уу.

Холбогдох баримт бичиг - ST-5

Урьдчилсанview ACEMIC Q2 Dual Channel Wireless Microphone System User Guide
Comprehensive user guide for the ACEMIC Q2 Dual Channel Wireless Microphone System, detailing features, setup, operation, and technical specifications for various microphone models including Accordion, Saxophone, Handheld, Headset, Lavalier, and Fitness types.
Урьдчилсанview ACEMIC PR-8/ST-4 Wireless Saxophone Microphone User's Manual
User's manual for the ACEMIC PR-8/ST-4 Wireless Saxophone Microphone system, detailing features, specifications, setup, and operation for musicians.
Урьдчилсанview ACEMIC RE-10 Wireless Microphone for Musical Instruments User Manual
User manual for the ACEMIC RE-10 digital wireless microphone system. Learn about its components, features, specifications, and setup for musical instruments, suitable for stage and street performances.
Урьдчилсанview ACEMIC ACE-288 Wireless Microphone System User's Manual
User's manual for the ACEMIC ACE-288 Wireless Microphone System, detailing system overview, features, specifications, receiver and transmitter components, and setup instructions for musical instruments.
Урьдчилсанview ACEMIC V1 Wireless Transmitter System User Manual
User manual for the ACEMIC V1 wireless transmitter and receiver system, detailing setup, operation, specifications, and troubleshooting for cameras and smartphones.
Урьдчилсанview ACEMIC RT-1 Plug-on Wireless Transmitter and Receiver User Guide
User guide for the ACEMIC RT-1 plug-on wireless transmitter and receiver system, detailing product functions, accessories, operation, troubleshooting, and technical specifications for professional audio applications.