1. Танилцуулга

The DSC PG9985 PowerSeries Neo Wireless PowerG Flood Detector is designed to provide early warning of water leaks and potential flooding in residential and commercial environments. This device utilizes PowerG wireless technology for secure and reliable communication with compatible DSC PowerSeries Neo security systems. It is an essential component for protecting property from water damage by detecting the presence of water at critical locations.

2. Аюулгүй байдлын мэдээлэл

Please read and understand all safety instructions before installing and operating this device. Failure to follow these instructions may result in damage to the product, property, or personal injury.

3. Багцын агуулга

Бүх зүйл багцад байгаа эсэхийг шалгана уу:

4. Бүтээгдэхүүн дууссанview

The DSC PG9985 consists of a main wireless transmitter unit and a wired flood sensor probe. The main unit communicates with your security system, while the probe detects water.

DSC PG9985 Wireless Flood Detector main unit and wired probe

Зураг 1: DSC PG9985 Wireless Flood Detector, showing the main unit connected to the wired sensor probe. The main unit is a compact white rectangular device, and the probe is a flat, white component with two metal contacts at its base, designed to be placed on a surface.

DSC PG9985 Wireless Flood Detector vertical view

Зураг 2: DSC PG9985 Wireless Flood Detector in a vertical orientation, highlighting the connection between the main unit and the wired sensor probe. This view emphasizes the compact design of both components.

4.1 дугаартай. Бүрэлдэхүүн хэсгүүд

5. Тохиргоо ба суурилуулалт

Proper installation is crucial for the reliable operation of the flood detector.

5.1. Зай суурилуулах

  1. Үндсэн нэгжийн c-г нээнэ үүasing.
  2. Insert the specified Lithium battery, observing correct polarity.
  3. c-г хаахasing securely. The LED may flash to indicate power-up.

5.2. Үндсэн төхөөрөмжийг суурилуулах

The main unit is designed for tabletop mounting or wall mounting near the area to be monitored. Ensure it is placed in a dry location, away from direct contact with water.

5.3. Placing the Flood Sensor Probe

The flood sensor probe should be placed at the lowest point of the area where water accumulation is expected.

5.4. Enrolling with the PowerSeries Neo System

Refer to your PowerSeries Neo control panel's installation manual for specific enrollment procedures. Generally, the steps involve:

  1. Access the system's programming menu.
  2. Select the option to add a new wireless device or zone.
  3. Activate the flood detector (e.g., by pressing a tamper switch or triggering a flood event) to transmit its unique ID to the panel.
  4. Assign the detector to an appropriate zone and configure its attributes (e.g., 24-hour flood zone).
  5. Test the communication and flood detection functionality.

6. Ашиглалтын заавар

Once installed and enrolled, the PG9985 operates automatically.

6.1. Water Detection

When water bridges the two metal contacts on the sensor probe, the detector will immediately transmit a flood alarm signal to the PowerSeries Neo control panel. The panel will then initiate the programmed response, which may include sounding an alarm, sending notifications, or activating other connected devices.

6.2. Статусын үзүүлэлт

The LED on the main unit provides visual status indications:

6.3. Testing the Detector

Regular testing ensures the detector is functioning correctly.

  1. Place a small amount of water (e.g., a few drops) on the metal contacts of the sensor probe.
  2. Observe the main unit's LED for a rapid flash, indicating an alarm transmission.
  3. Verify that your PowerSeries Neo system receives the flood alarm.
  4. Dry the sensor probe thoroughly after testing.

7. Засвар үйлчилгээ

Minimal maintenance is required to keep your flood detector in optimal condition.

7.1. Зай солих

When the system indicates a low battery for the PG9985, replace the battery promptly to ensure continuous protection.

  1. Disarm your security system to prevent false alarms during battery replacement.
  2. Үндсэн нэгжийн c-г нээнэ үүasing.
  3. Remove the old battery and insert a new Lithium battery of the same type, ensuring correct polarity.
  4. c-г хаахasing найдвартай.
  5. Test the detector after battery replacement to confirm proper operation.

7.2. Цэвэрлэгээ

Periodically inspect the sensor probe for dirt, dust, or corrosion on the metal contacts. Clean with a soft, dry cloth. Do not use abrasive cleaners or solvents.

7.3. Тогтмол туршилт

It is recommended to test the flood detector at least once a month to ensure its functionality. Refer to Section 6.3 for testing procedures.

8. Алдаа засах

If you encounter issues with your flood detector, refer to the following common problems and solutions.

АсуудалБоломжит шалтгаанШийдэл
Detector does not respond to water.Батарей цэнэггүй эсвэл бага.
Sensor contacts are dirty or corroded.
Probe not making proper contact with water.
Device not enrolled or configured correctly.
Зайг солих.
Clean sensor contacts.
Reposition probe to ensure contacts are submerged.
Verify enrollment and zone programming in the control panel.
Хуурамч дохиолол.Condensation or moisture on contacts.
Probe placed in an area with high humidity.
Faulty probe or main unit.
Ensure contacts are dry.
Relocate probe to a drier area if possible.
Contact technical support if problem persists.
Батерей багатай гэсэн дохио.Battery is nearing end of life.Зайг яаралтай солино уу.
No communication with control panel.Хязгаараас гарсан.
Хөндлөнгийн оролцоо.
Device not enrolled.
Relocate detector closer to the control panel or a wireless repeater.
Check for sources of interference.
Re-enroll the device.

If troubleshooting steps do not resolve the issue, contact your security system installer or technical support.

9. Техникийн үзүүлэлтүүд

ОнцлогДэлгэрэнгүй
Загварын дугаарPG9985
БрэндDSC
Мэдрэгч технологиУсны мэдрэгч
Хяналтын аргаTouch (for enrollment/testing)
Суурилуулах төрөлШирээний тавиур
Эрчим хүчний эх үүсвэрБатерейгаар ажилладаг
Зайны төрөлLithium (specific type not provided, refer to device label)
Зүйлийн жинОйролцоогоор 1 фунт
Бүтээгдэхүүний хэмжээсОйролцоогоор 1 x 1 x 1 инч (үндсэн хэсэг)
ӨнгөЦагаан
UPC738714001753

10. Баталгаат хугацаа ба дэмжлэг

For warranty information, please refer to the documentation provided with your DSC PowerSeries Neo security system or contact your authorized DSC dealer. Technical support is typically provided by your security system installer or the dealer from whom you purchased the product.

For further assistance, please contact your local DSC representative or visit the official DSC webсайт.

Холбогдох баримт бичиг - PG9985

Урьдчилсанview DSC PowerSeries Neo PowerG Device ERP Quick Reference Guide
Quick reference guide for DSC PowerSeries Neo compatible PowerG devices, detailing 915MHz frequency, power variability, and transmission power (ERP) in dBm for various detectors, sirens, keys, and repeaters.
Урьдчилсанview PGPx986 Хөлдөлт илрүүлэгчтэй PowerG+ усны хавтанцар суурилуулах гарын авлага
Installation guide for the Johnson Controls/DSC PGPx986 PowerG+ Water Tile with Freeze Detection. Learn how to install, enroll, and test this advanced water leak and freeze detection sensor for enhanced home or business security.
Урьдчилсанview HS2TCHP E Touchscreen User Manual - DSC Security
User manual for the DSC HS2TCHP E Touchscreen, providing instructions and information on its features, operation, and safety for PowerSeries Neo and Pro alarm systems.
Урьдчилсанview Troubleshooting DSC PowerSeries Neo Installer Code Validation Errors
A guide to resolving the "Your Installer Code has Not Been Validated" error on DSC PowerSeries Neo panels, ensuring proper communication with Alarm.com.
Урьдчилсанview DSC PowerSeries Neo HS2016/2032/2064/2128 дохиоллын самбар хэрэглэгчийн гарын авлага
DSC PowerSeries Neo HS2016, HS2032, HS2064, HS2128 дохиоллын самбарт зориулсан хэрэглэгчийн иж бүрэн гарын авлага нь системийн ажиллагаа, зэвсэглэх, зэвсэглэх, нэвтрэх код, алдааг олж засварлах, орон сууцны болон худалдааны хамгаалалтын системийн аюулгүй байдлын зааварчилгааг багтаасан.
Урьдчилсанview DSC PG4914/PG8914/PG9914 PowerG утасгүй хөдөлгөөн мэдрэгч суурилуулах гарын авлага
DSC PG4914, PG8914, PG9914 PowerG утасгүй PIR хөдөлгөөн мэдрэгчийг суурилуулах заавар. Таны DSC хамгаалалтын системийн онцлог, суулгах журам, тохиргоо болон алдааг олж засварлах талаар мэдэж аваарай.