DROK Bidirectional Volt Amp Meter (Model 200536FBA) Instruction Manual

Танилцуулга

This manual provides detailed instructions for the installation, operation, and maintenance of the DROK Bidirectional Volt Amp Meter, Model 200536FBA. This 7-in-1 monitor is designed to measure DC voltage, current, power, battery capacity, amp-hour, watt-hour, and time, featuring a clear color LCD display and a Hall sensor for non-contact current measurement.

Бүтээгдэхүүний онцлог

Багцын агуулга

Бүх зүйл багцад байгаа эсэхийг шалгана уу:

DROK Bidirectional Volt Amp Meter components including display, Hall sensor, and connecting wires.

Image: The complete package contents, showing the display unit, Hall sensor, and the included shielding wire.

Үзүүлэлтүүд

ПараметрҮнэ цэнэ
Хэмжих параметрүүдБотьtage, Current, Power, Battery Capacity, Amp-Hour, Watt-Hour, Time
Ботьtage Хэмжилтийн хүрээDC 0-90V хувилбартай
Одоогийн хэмжлийн хүрээDC 0-300А
Ботьtage Хэмжилтийн нарийвчлал± 2% ± 5 оронтой
Одоогийн хэмжилтийн нарийвчлал± 3% ± 5 оронтой
Дэлгэцийн нягтрал0.1A, 0.01V, 0.01AH, 0.01H (1 min)
Хэмжилтийн хувь5 удаа / секунд
Дэлгэц1.8 inch LCD Color Screen
Meter Overall Dimension79 x 43 x 26mm (3.11 x 1.69 x 1.02 инч)
Meter Opening Hole Size76.5 x 39.2 мм (3.01 x 1.54 инч)
Холл мэдрэгчийн хэмжээ57 x 32 x 50mm (2.24 x 1.26 x 1.97 inch) (with screw and copper pillars)
Hall Sensor Hole Diameter20мм (0.79 инч)
Хэт ботьtage Хамгаалалт (OVP)0.01V-90V
Хэт их гүйдлийн хамгаалалт (OCP)0.1-100A
Хэт эрчим хүчний хамгаалалт (OPP)0.01Вт-9.99КВт
Бага ботьtage Protection (LOP)0.01V-90V
Over-Charge Protection (OAH)0.01AH-9999AH
Over-Time Protection (OFT)1мин-99цаг59мин
Dimensions of the DROK display unit and Hall sensor.

Image: Physical dimensions of the display unit and the Hall sensor for installation planning.

Тохиргоо ба суурилуулалт

Proper wiring is crucial for accurate measurements and safe operation. The Hall sensor measures current by passing the load wire through its central hole. The display unit requires a power supply (DC 10-60V) and connects to the Hall sensor via the provided shielding wire.

Wiring diagrams for the DROK Bidirectional Volt Amp Meter in three configurations.

Image: Three common wiring configurations for the meter, showing connections to battery, load, and optional relay.

Wiring Configuration 1: Basic Monitoring (Self-Powered)

In this configuration, the meter is powered directly from the battery being monitored. This is suitable for systems where the battery voltage is within the meter's operating range (10-60V).

  1. Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
  2. Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
  3. нэвтрүүлэх сөрөг load wire through the central hole of the Hall sensor. Ensure the direction of current flow through the sensor matches the arrow on the sensor for correct bidirectional readings.
  4. Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
  5. Ensure the jumper cap on the Hall sensor is placed to select the self-powered mode (typically labeled '10-60V' or similar, check the sensor board for exact markings).

Wiring Configuration 2: External Power Supply

Use this configuration when the battery voltage is outside the meter's operating range (e.g., 0-10V or above 60V) or if you prefer a separate power source for the meter.

  1. Connect the positive terminal of the battery to the 'Bat+' terminal on the Hall sensor.
  2. Connect the negative terminal of the battery to the 'Bat-' terminal on the Hall sensor.
  3. нэвтрүүлэх сөрөг load wire through the central hole of the Hall sensor.
  4. Connect the display unit to the Hall sensor using the provided 50cm shielding wire.
  5. Connect an external DC power supply (10-60V) to the 'Vext+' and 'Vext-' terminals on the Hall sensor.
  6. Remove the jumper cap from the Hall sensor to enable external power mode.

Wiring Configuration 3: With Relay for Output Control

This setup allows the meter to control an external relay (not included) based on configured protection parameters (e.g., over-current, low-voltage).

  1. Follow either Configuration 1 or 2 for basic power and measurement connections.
  2. Connect the relay's control terminals to the 'Relay+' and 'Relay-' terminals on the Hall sensor.
  3. Ensure the jumper cap is set correctly for the chosen power mode (self-powered or external).
  4. The meter's output control button can then be used to enable/disable the relay, or the relay can be triggered automatically by protection settings.

Ашиглалтын заавар

The DROK Volt Amp Meter features a user-friendly interface with a color LCD and three control buttons: Up, OK, and Down.

Урд view of the DROK Bidirectional Volt Amp Meter display showing various readings and protection indicators.

Image: The main display interface, showing voltage, current, capacity, power, time, and protection status indicators.

Дэлгэцийг харуулахview

The 1.8-inch color LCD simultaneously displays:

Товчлуурын функцууд

Resetting AH and Time

To reset accumulated Amp-Hours (AH) and Time, navigate to the relevant display screen using the arrow buttons. Press and hold the OK button until the values reset. This is useful for monitoring specific charge/discharge cycles.

Шалгалт тохируулгын журам

For optimal accuracy, calibration may be required. Follow these steps carefully:

  1. Шалгалт тохируулгын горимыг оруулна уу: Төхөөрөмж унтарсан үед товчлуурыг удаан дар OK button. While holding OK, switch the power to the device ON. Release the OK button as soon as the display illuminates.
  2. Navigation in Calibration Mode: In calibration mode, press the OK button to move from one menu item to the next. Use the Up болон Доош arrow keys to adjust values.
  3. Zero Current Calibration: Before calibrating current readings, ensure no current is flowing through the Hall sensor. Switch off all loads. Press OK until the "0.0 A" option is selected, then press the Доош arrow once to zero out the current reading.
  4. Positive Current Calibration (+A): To calibrate current in the charging direction, ensure current is flowing from the charging source into your battery. Press OK until the "+A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
  5. Negative Current Calibration (-A): To calibrate current in the discharging direction, ensure current is flowing out of your battery into your loads. Press OK until the "-A" option is selected, then use the arrow keys to adjust the reading to match a known accurate current measurement.
  6. Тохиргоог хадгалах: After completing all calibrations, navigate the cursor to the "Save" option using the OK button. Select "Save" to store your settings.
  7. Exit Calibration Mode: To exit calibration mode, simply switch the power to the unit OFF, then ON again.

Хамгаалалтын функцууд

The meter includes several programmable protection functions to safeguard your system:

When a protection limit is reached, the meter can activate an external relay (if connected) to disconnect the load or charging source.

Бусад функцууд

Засвар үйлчилгээ

The DROK Bidirectional Volt Amp Meter is designed for durability and requires minimal maintenance.

Алдааг олж засварлах

Баталгаат болон дэмжлэг

Specific warranty information for the DROK Bidirectional Volt Amp Meter (Model 200536FBA) is not provided in this manual. For warranty claims, technical support, or further assistance, please refer to the product packaging, the seller's website, or contact DROK customer service directly.