This manual provides essential information for the safe and proper installation, operation, and maintenance of your Veepeak 30 Amp Flanged Outlet NEMA L14-30R Locking Receptacle. Please read all instructions carefully before installation and use. Retain this manual for future reference.
Аюулгүй байдлын мэдээлэл
АНХААРУУЛГА: Electrical shock hazard. Improper installation or use can result in serious injury or death. Always follow local electrical codes and consult a qualified electrician if you are unsure about any part of the installation process.
- Энэ төхөөрөмжийг суурилуулах эсвэл үйлчилгээ үзүүлэхийн өмнө хэлхээний таслуур эсвэл гал хамгаалагчийн хайрцгийн цахилгааныг үргэлж салгаж байгаарай.
- Ensure all wiring connections are secure and correct according to the wiring diagram and local codes.
- Төхөөрөмжийн тогтоосон цахилгааны үзүүлэлтээс хэтрүүлж болохгүй.
- This product is designed for use with NEMA L14-30P compatible plugs only.
- Keep the weatherproof cap closed when the outlet is not in use to protect against moisture and dust.
Багцын агуулга
- 1 x Veepeak 30 Amp NEMA L14-30R Flanged Outlet
- Суурилуулалтын эрэг
Үзүүлэлтүүд
| Тодорхойлолт | Үнэ цэнэ |
|---|---|
| Ampарилгах | 30 Amps |
| Ботьtage | 125/250 вольтын хувьсах гүйдэл |
| ОБЕГ-ын тохиргоо | L14-30R |
| Шон / Утаснууд | 3 Pole, 4 Wire Grounding |
| Хамгийн их ачаалал | 7500 ватт |
| Санал болгож буй утас хэмжигч | 10 AWG/4C |
| Материал | Поливинил хлорид (PVC) |
| Гэрчилгээ | ETL Listed (Conforms to UL & CSA standards) |
| Шаардлагатай нүхний хэмжээ | 2.5 инч |
Тохиргоо ба суурилуулалт
Шаардлагатай хэрэгслүүд: Screwdriver, wire strippers, drill (for mounting hole), appropriate drill bit.
- Суулгах байршлыг бэлтгэх: Choose a suitable, dry location for installation. Drill a 2.5-inch diameter hole for the receptacle body. Ensure there is enough space behind the mounting surface for wiring connections.
- Утасны холболтууд:
Refer to the wiring diagram below and the color-coded terminals on the back of the receptacle. Strip approximately 1/2 inch of insulation from each wire. Insert the wires into the corresponding terminals and tighten the screws securely. Ensure no bare wire strands are exposed outside the terminals.

Зураг: Ар талд view of the L14-30R outlet, displaying the four color-coded terminals for wiring connections (Green for Ground, White for Neutral, Red and Black for Hot).

Image: NEMA L14-30R configuration diagram. 'X' and 'Y' are hot lines (125V each to neutral, 250V between them), 'W' is neutral, and 'G' is ground.
- Green (G): Газардуулгын утас.
- Цагаан (W): Төвийг сахисан утас.
- Black (X): Hot wire (Line 1).
- Red (Y): Hot wire (Line 2).
- Mount the Receptacle: Insert the receptacle body into the drilled hole. Secure the flanged outlet to the mounting surface using the provided screws. Ensure it is flush and stable.
- Эрчим хүчийг сэргээх: Суурилуулалт дуусч, бүх холболтыг шалгасны дараа таслагчийн хүчийг сэргээнэ үү.

Зураг: Урд view of the Veepeak L14-30R flanged outlet with its weatherproof cap open, revealing the NEMA L14-30R locking receptacle.
Ашиглалтын заавар
- Opening the Cap: Lift the weatherproof cap to access the receptacle.
- Залгуурыг холбох: Align the NEMA L14-30P plug with the receptacle. Insert the plug and twist clockwise to lock it into place. Ensure the plug is fully seated and locked.
- Залгуурыг салгах: Twist the plug counter-clockwise to unlock, then pull it straight out from the receptacle.
- Closing the Cap: When the outlet is not in use, ensure the weatherproof cap is securely closed over the receptacle to protect it from environmental elements like rain, snow, and dust.

Зураг: Урд view of the Veepeak L14-30R flanged outlet with its weatherproof cap securely closed, providing protection.
Засвар үйлчилгээ
Тогтмол засвар үйлчилгээ нь оновчтой гүйцэтгэл, аюулгүй байдлыг хангадаг.
- Цэвэрлэгээ: Periodically clean the exterior of the outlet with a damp cloth. Do not use abrasive cleaners or solvents. Ensure the cap is closed during cleaning.
- Шалгалт: Regularly inspect the outlet for any signs of damage, wear, or corrosion. Check the weatherproof cap for proper sealing.
- Холболт шалгах: Annually, or if issues arise, disconnect power and check the wiring connections for tightness. Loose connections can cause overheating.
Алдааг олж засварлах
- Эрчим хүчгүй:
- Check the circuit breaker or fuse for the circuit. Reset if tripped.
- Эрчим хүчний эх үүсвэр идэвхтэй байгаа эсэхийг шалгана уу.
- Ensure the plug is fully inserted and locked into the receptacle.
- Сул холболт:
- If the plug feels loose or power is intermittent, disconnect power and inspect the wiring connections at the back of the receptacle for tightness.
- Inspect the plug on the appliance for damage.
- Damage to Outlet:
- If the outlet housing or terminals show signs of damage, cracking, or burning, discontinue use immediately and replace the unit.
Хэрэв алдааг олж засварлах арга нь асуудлыг шийдэж чадахгүй бол мэргэшсэн цахилгаанчинтай зөвлөлд.
Баталгаат болон дэмжлэг
Veepeak provides a one-year hassle-free replacement warranty for this product. For warranty claims or customer service inquiries, please contact Veepeak customer support through the retailer where the product was purchased or visit the official Veepeak webсайт.