SKYTECH 3003P Remote Kit

ТАНИЛЦУУЛГА
This remote control system was developed to provide a safe, reliable, and user-friendly remote control system for gas heating appliances. The system can be operated thermostatically, manually, or with the built-in factory program inside the transmitter. The built-in program will control the appliance (7) days a week with (4) continuous time periods for each day. SEE PROGRAM SEQUENCE BELOW. Custom programming may be achieved after the initial set has been performed. This system operates on radio frequencies (RF) within a 20-foot range using non-directional signals. The system operates one of 1,048,576 security codes that are programmed into the transmitter at the factory; the remote receiver’s code must be matched to that of the transmitter prior to initial use.

Review COMMUNICATION SAFETY under the TRANSMITTER SECTION and THERMO SAFETY under the REMOTE RECEIVER SECTION. These signal/temperature safety features shut down the appliance when a potentially unsafe condition exists.
The transmitter operates on (2) AAA 1.5V batteries. It is recommended that ALKALINE batteries always be used for longer battery life and maximum operational performance. IMPORTANT: New batteries are essential for the proper operation of the multi-function transmitter.
INITIAL SET-UP OF TRANSMITTER
The initial set-up of the transmitter is IMPERATIVE to ensure the following:
- Current Time – Hours and Minutes / AM/PM
- Current Day of the Week – S, M, T, W, T, F, S
- Proper Temperature Scale – F° (Fahrenheit) or°C (Celsius)
To begin the initial set-up, proceed with the following steps:
- Remove the battery cover on the back of the transmitter. Insert (2) ALKALINE AAAA-size1.5 DCV batteries into the battery compartment, positioning the (+) and (-) ends of the batteries as indicated on the casing. When the batteries are inserted properly, the LCD screen will display.

- Note the small button at the upper left side of the battery compartment (Fig. 1). This button is used to perform the initial transmitter set-up.
- Push and release the setting button on the back of the transmitter with a paper clip or the sharp end of a pencil (Fig.1). The °F temperature scale sign will be blinking on the LCD screen (Fig. 2). Press the UP or Down but-tons on the transmitter to change from °F (Fahrenheit) or °C (Celsius). After confirming the preferred temperature scale, open the transmitter cover and press the SET button to confirm your setting.

- After confirming the temperature scale, the symbol “S” will begin blinking on the LCD screen (Fig. 3). This is to set the day of the week. The “S” at the top left portion of the screen is for Sunday. To change the day of the week, use the AHEAD or BACK buttons. After confirming the day of the week, press the SET button.
- After confirmingthe day of the week, the HOUR digits will begin blinking on the screen (Fig. 4). Press the UP or DOWN buttons to set the hour corresponding with the AM/PM time period. Press the SET button to confirm the hour of the day

NOTE: If a LOW battery icon appears on the screen, check the position of the batteries.
АНХААРУУЛГА: Дамжуулагчийн температурыг хянах мэдрэмтгий бүрэлдэхүүн хэсгүүдийн улмаас өрөөний температурыг дэлгэц дээр харуулахаас өмнө дамжуулагчийг өрөөний температурт тогтворжуулах шаардлагатай. Хүйтний хүнд нөхцөлд дамжуулагчийг идэвхжүүлсэн тохиолдолд температурын нарийвчлалыг харуулах хүртэл арван таван минут зарцуулагдана.
LCD ДЭЛГҮҮРИЙН функцууд
- PROGRAM FOR: Flashes when programming days of the week and periods of the day. When in the normal state, only the current DAY displays. When programming or in PROGRAM mode, both day periods appear.
- DAY: Flashes when the current day or day of the week is being programmed.
- PERIOD: Flashes when the current period of the day or the period of the week is being programmed.
- MODE: Indicates the operation MODE of the system.
- ON indicates the system is ON, manually, thermostatically, or programmatically.
- Off indicates the entire system is turned OFF.
- THERMO indicates the system will automatically cycle ON/OFF, depending on the desired or preset SET temperature.
- PROGRAM – shows system is operating with PROGRAMMED settings.
- LOW: Battery power is low. Replace batteries within 2 weeks.
- START AT: Flashes when programming the time to turn the system ON.
- SET: Indicates desired SET room temperature, when in THERMO or PROGRAM mode.
- Indicates Fahrenheit (°F) and Celsius (°C) settings.
- TIME/TEMP: Displays CURRENT room temperature. In the same frame, the current time will display in AM or PM. You must depress the TIME/TIMER button to display the current time.
- TIMER: When displayed, indicates the countdown timer in operation.
- OVERRIDE: Displays if the “programmed” SET temperature is overridden.
- FLAME: A single flame symbol indicates the burner/valve is operational.
- HOLD: Displays when “programmed” SET temperature is overridden and will hold that temperature until cancelled.
- CP: Displays when CHILD PROOF “LOCK OUT” is engaged. Pressing the UP and TIMER buttons togetherenengagesr disengages CP.
- SWING: Displays in the SET frame when setting TEMPERATURE DIFFERENTIAL.

ДАМЖУУЛАГЧИЙН ҮНДСЭН ҮЙЛ АЖИЛЛАГАА
To operate the transmitter, first press and release the MODE button (Fig. 7) until the LCD screen reads OFF in the display (See Fig. 8).
- Step 1: Press the MODE button one time to manually turn ON the appliance (Fig. 9).
- Step 2: Press the MODE button a second time to put the system in THERMO mode (Fig. 10).
- Step 3: Press the MODE button a third time to put the system in PROG (Program) mode (Fig. 11).
- Step 4: Press the MODE button a fourth time to turn the appliance back OFF again, as shown in Fig. 8.

СУУЛГАХ ЗААВАР
This remote control system must be installed exactly as outlined in these instructions. Read all instructions completely before attempting installation. Follow instructions carefully during installation. Any modifications of the Model remote control or any of its components will void the warranty and may pose a fire hazard. Do not connect any gas valve or electronic module directly to 110-120VAC power. Consult the gas appliance manufacturer’s instructions and wiring schematics for proper placement of all wires. All electronic modules are to be wired tothe manufacturer’s specifications. The following wiring diagrams are for illustrative purposes only. Follow instructions from the manufacturer of the gas valve and/or electronic module for correct wiring procedures. Improper installation of electric components can cause damage to the electronic module, gas valve,e and remote receiver.
СУУРИЛУУЛАЛТ
The remote receiver can bwall-mounteded into a standard plastic switch box or (hearth-mounted) placed on or near the fireplace hearth. Determine where you will install the receiver before proceeding. Preferably, the remote receiver should be wall-mounted in a plastic switch box, as this will protect its electronic components from both the heat produced by the gas appliance and potential damage or abuse that can occur if it is left exposed on the hearth. PROTECTION FROM EXTREME HEAT IS VERY IMPORTANT. Like any piece of electronic equipment, the receiver should be kept away from temperatures exceeding 130°F inside the receiver case. Battery life is also significantly shortened if batteries are exposed to high temperatures. Ensure the receiver switch is in the OFF position before installing. It is recommended that18-gaugee stranded or solid wires (not included) be used to make connections between the terminal wiring block on the millivolt gas valve or electronic module and the wire terminals on the remote receiver. For the best results, use 18-gauge stranded or solid wire, splice into the black wires of the receiver, or remove the black wires and install wires directly to the receiver. Be sure no splices
measure longer than20 feett and allow ampжил бүр зайгаа солихын тулд хүлээн авагчийг салгах утас.
ХААН ХАСГАЛТ
Эхлээд (4) АА хэмжээтэй 1.5 ШҮЛТЛЭГ зайг алсын хүлээн авагчид суулгана (Зураг 12). Хамгийн сайн гүйцэтгэлтэй байхын тулд алсын зайнаас хүлээн авагчийн батерейг суурилуулахдаа үйлдвэрээс гарсан шинэхэн байх ёстой. Батерейны гаралт 5.3 вольтоос их байх үед систем хамгийн сайн ажилладаг. Дөрвөн (4) шинэ АА батерей нь гаралтын хэмжээг өгөх ёстойtage 6.0-6.2 вольт. Батерейг (+) ба (-) төгсгөлүүд нь зөв зүг рүү чиглүүлж суулгасан эсэхийг шалгаарай.

Дараа нь хананд бэхэлгээний хавтанг хүлээн авагчийн хайрцагт холбоно (Зураг 13):
Position the receiver as shown in the diagram to the left, withthe lower tab on the wall mount cover plate inserted into the groove of the receiver. Move the receiver up and snap it into the top tab of the cover plate. Position the cover plate so the word ON is facing up (Fig. 14); then, install the remote receiver into the plastic switch box using the two long screws provided. Push the slide button over the receiver slide switch only after making sure the remote receiver has LEARNED the transmitter’s security code (see LEARNING TRANSMITTER TO RECEIVER). 
ЗАЛУУН УУЛ
The remote receiver can be placed on the fireplace hearth or under the fireplace, behind the control access panel or louvers. Position where the ambient temperature inside the receiver case does not exceed 130°F. NOTE: Slide Button (included) is used for Hearth Mount applications (Fig. 15).
Утас тавих заавар
A qualified electrician or a gas technician who is trained with gas appliances and gas valves that will be operated by this remote should install the remote control system. Incorrect wiring connections WILL cause damage to the gas valve or electronic module operating the gas appliance,e and may also damage the remote receiver.
МИЛИВОЛТЫН УТАСНЫ УТАСНУУД
The remote receiver must be connected to the millivolt valve at the TH & TH/TP (thermostat) terminals on the terminal block on the millivolt gas valve. Connec18-gaugege stranded or solid wires from the remote receiver to the gas valve. The operation of the remote receiver is similar to that of a thermostat in that both turn the gas valve on and off based on input signals. A thermostat’s input signals are different temperatures. The remote receiver’s input signals come from the transmitter. Connect one black wire to the TH terminal and the other black wire to the TH/TP terminals on the millivolt gas valve. Normally, it does not matter which wires go to which terminal (Fig. 16). 
ЭЛЕКТРОН ОЧЛОЛТЫН УТАС
The remote control receiver can be connected, in series, to a 24VAC transformer to the TR (transformer) terminal on the ELEC-TRONIC MODULE. Connect the hot wire from the 24VAC transformer to either of the wire terminals on the remote receiver. Connect another wire (not included) between the other receiver wire terminal and the TH (thermostat) terminal on the ELECTRONIC MODULE (Fig. 17).
ХҮЛЭЭН АВАХ ХҮЛЭЭН АВАХ СУРГАЛТ
Each transmitter uses a unique security code. It will be necessary to press the LEARN button on the receiver to accept the transmitter security code upon initial use, if batteries are replaced, or if a replacement transmitter is purchased from your dealer or the factory. In order for the receiver to accept the transmitter security code, be sure the slide button on the receiver is in the REMOTE position; the receiver will not LEARN if the slide switch is in the ON or OFF position. The LEARN button is located on the front face of the receiver, inside the small hole labeled LEARN. Using a small screwdriver or ethe nd of a paperclip, gently press and release the black LEARN button inside the hole. When you release the LEARN button,n the receiver will emit an audible “beep”. After the receiver emits the be, ep press the transmitter MODE button and release. The receiver will emit several beeps indicating that the transmitter’s code has been accepted into the receiver. The microprocessor that controls the security code matching procedure is controlled by a timing function. If you are unsuccessful in matching the security code on the first attempt, wait 1-2 minutes before trying again – this delay allows the microprocessor to reset its timer circuitry – and try up to two or three more times. 
СИСТЕМИЙН ХЯНАЛТ
Милливольт клапан
Light the gas appliance following the lighting instructions that came with the appliance. Confirm that the pilot flame is ON, and the control knob on the gas valve is in the ON position for the main gas valve to operate.
- Slide the 3-position button on the remote receiver to the ON position. The main gas flame (fire) should light.
- Товчлуурыг OFF руу гулсуулна уу. Дөл унтрах ёстой (нисгэгчийн дөл хэвээр байх болно).
- Slide the button to REMOTE (the center position), and then press the MODE button on the transmitter to change
the system to ON. The main gas flame should ignite. - Press the MODE button on the transmitter to change the system to OFF. The flame should extinguish (the pilotThe
flame will remain on. - Press the MODE button on the transmitter to change the system to THERMO. Advance the SET temperature on the transmitter to a temperature of at least 2°F (1°C) above the ROOM temperature displayed on the LCD screen. With this manual setting, the normal thermostatic cycle is overridden, and the system flame will ignite. Place the SET temperature to at least 2°F (1°C) below the room temperature,e and the system flame will extinguish in a few seconds. Thereafter, it should continue to cycle on and off thermostatically approximately every two minutes as the ROOM temperature changes, but only when the temperature differential between ROOM and SET temperature differs at least 2°F (1°C). (The 2differentialial is the factory setting.)
ЦАХИЛГААН АСАЛТЫН СИСТЕМ
- Slide the 3-position button on the remote receiver to the ON position. The spark electrode should begin sparking to ignite the pilot (the pilot may ignite after only one spark). After the pilot flame is lit, the main gas valve should op, en and the main gas flame should ignite.
- Товчлуурыг OFF руу гулсуулна уу. Гол хийн дөл ба нисгэгчийн дөл хоёулаа унтрах ёстой.
- Slide the button to REMOTE (the center position), and then press the MODE button on the transmitter to change the system to ON. The spark electrode should begin sparking to ignite the pilot. After the pilot is lit, the main gas valve should open, and the main gas flame should ignite.
- Дамжуулагч дээрх MODE товчийг дарж OFF болгоно. Гол хийн дөл ба нисгэгчийн дөл хоёулаа унтрах ёстой.
- Press the MODE button on the transmitter to change the system to THERMO. Advance the SET temperature on the transmitter to a temperature at least 2°F (1°C) above the ROOM temperature displayed on the LCD screen. With this manual setting,g the normal thermostatic cycle is overridden, en and the system flame will ignite. Place the SET temperature at least 2°F (1°C) below the room temperature,ure and the system flame will extinguish in a few seconds. Thereafter, it should continue to cycle ON and OFF thermostatically approximately every two minutes as the ROOM temperature changes, but only when the temperature differential between ROOM and SET temperatures differs at least 2°F (1°C). (The 2°F differential is the factory setting.)
ЕРӨНХИЙ МЭДЭЭЛЭЛ
АЛСЫН ХҮЛЭЭН АВАГЧ
The remote receiver houses the microprocessor that responds to commands from the transmitter to control the system operation. It emits one beep when it receives an ON or OFF command manually, but no beep when cycling ON and OFF automatically in THERMO mode. The remote receiver has a 3-position slide switch for selecting the MODE of operation: ON/REMOTE/OFF.
- Гулсуурын унтраалга ON байрлалд байгаа үед гулсуур унтраалгыг OFF эсвэл REMOTE байрлалд байрлуулах хүртэл систем "гараар" асаалттай хэвээр байх болно.
- Слайд шилжүүлэгчийг REMOTE (төв) байрлалд (төв байрлуулсан) үед алсын хүлээн авагч нь дамжуулагчаас тушаал хүлээн авсан тохиолдолд л систем ажиллана.
- Гулсуур унтраалга OFF байрлалд байх үед систем унтарсан байна.
- Хэрэв та гэрээсээ хол удаан хугацаагаар байх юм бол гулсуур унтраалгыг унтраах байрлалд байрлуулахыг зөвлөж байна. Алсын хүлээн авагчийг хүүхдийн гар хүрэхгүй газар суурилуулсан бол гулсуурын унтраалгыг OFF байрлалд байрлуулах нь системийг унтрааж, алсын хүлээн авагчийг ажиллахгүй болгох замаар аюулгүй байдлын "түгжих" үүрэг гүйцэтгэдэг.
ТЕРМО- АЮУЛГҮЙ БАЙДЛЫН ОНЦЛОГ – ХҮЛЭЭГЧ (T/S –RX)
This remote control has a THERMO-SAFETY feature that is built into the system’s RECEIVER. This feature is temperature-activated and provides an extra margin of safety when the RECEIVER is operating where ambient temperatures exceed 130°F inside the receiver case. The THERMO-SAFETY feature, in the RECEIVER, operates in the following manner when the appliance is in operation. The receiver is thermally protected from extreme heat conditions. Heat can have a negative effect on the operation of the receiver’s microprocessors. For REMOTE RECEIVERS that operate on BATTERY POWER, these heat conditions can cause batteries to discharge when temperatures exceed 115°F. Studies show that alkaline batteries, when exposed to a constant temperature of 115°F, can lose up to 50% of their operating power. When the battery cools down, it will partially recharge itself, but constant heating and cooling will reduce the battery’s normal life expectancy. When the ambient temperature at the THERMISTOR, inside the receiver case, reaches 130°F, the THERMISTOR will automatically shut the appliance down, a nd the RECEIVER will begin emitting a series of 3 “beeps” every 4 seconds. When the ambient temperature, at the RECEIVER, drops between 120°F and 130°F, the user can reactivate the appliance by pushing the MODE button on the transmitter. The word ON must display on the LCD screen. When the MODE button is pressed to ON, the THERMISTOR “resets” itself and the fireplace will begin operating again. However, the “beep-ing” will continue if the ambient temperature remains between 120°F and 130°F. This “beeping” alerts the user that the RECEIVER should be repositioned so the ambient temperature drops below 120°F. When the temperature drops below 120°F, the “beeping” will cease, provided the user has “reset” the THERMISTOR by pushing the MODE button OFF then ON to operate the appliance. Allow sufficient time for the receiver to cool below 120°F, and then press MODthe E button to stop beeping.
Дамжуулагч
OPERATING SAFETY MONITORS: SYSTEM SHUTDOWN
The remote control operates on RF (radio frequency) signals that are sent by the TRANSMITTER (remote) to the RE-CEIVER that operates the appliance. It is recommended that the TRANSMITTER always be located within the 20-foot operating range, preferably in the same room in which the appliance is located.
ДУЛААНЫ ШИНЭЧЛЭХ ОНЦЛОГ – ДАМЖУУЛАГЧ
This remote control has a THERMO UPDATING Feature built into its software. The THERMO UPDATING Feature ooperates inthe following manner, but only in the THERMO and PROGRAM MODES: The transmitter normally reads the ROOM temperature every 2 minute heckingg the ROOM temperature against the SET temperature by sending a signal to the receiver.
ХОЛБОО – АЮУЛГҮЙ БАЙДАЛ – ДАМЖУУЛАГЧ – (C/S – TX)
These seriesof f emote controls have a COMMUNICATION – SAFETY function built into the software. It provides an extra margin of safety when the TRANSMITTER is out of the normal 20-foot operating range of the receiver. The COMMUNICATION – SAFETY feature operates in the following manner for all OPERATING MODES: ON/THERMO/PROGRAM. At all times and in all OPERATING MODES, the transmitter sends an RF signal every fifteen (15) minutes to the receiver, indicating that the transmitter is within the normal operating range of 220 feet Sh.ould the receiver NOT receive a transmitter signal every 15 minutes, the IC software, in the RECEIVER w, ill begin a 2-HOUR (120-minute) countdown timing function. If during these 2 hours the receiver does not receive a signal from the transmitter, the receiver will shut down the fireplace being controlled by the receiver. The RECEIVER will then emit a series of rapid “beeps” for a period of 10 seconds. Then, after 10 seconds of rapid beeping, the RECEIVER will continue to emit a single “beep” every 4 seconds until a transmitter signal is again received. The intermittent4-secondd beeping will go on for as long as the receiver’s batteries last, which could be in excess of one year. To “reset” the RECEIVER and operate the fireplace system, you must press the MODE button on the transmitter. The word ON must display on the LCD screen. By turning the system to ON, the COMMUNICATION SAFETY operation is overridden, and the system will return to normal operation depending on the MODE selected at the transmitter. The COMMUNICATION SAFETY feature will reactivate should the transmitter be taken out of the normal operating range or should the transmitter’s batteries fail or be removed.
BUILT-IN PROGRAM
The transmitter has a built-in factory program, (7) days a week,k with (4) continuous time periods for each day. Each time period haits’s own starting time and temperature. A chart of the built- in programs is at the right. NOTE: The ending time for one period is the starting time for the next period. You may change any of the factory settings by following the procedures below. Should you desire to return to the factory program, follow the procedures under the eading PROGRAM REVIEW or PROGRAM CANCELLATION.
PROGRAMMING THE TRANSMITTER TO YOUR CUSTOM SETTINGS
The transmitter built-in program is the same for every day of the week. If desired, you may change a single day or all seven (7) days of the built-in program. Use the blank table on the next page and fill in your customized settings. To change one or all seven days,s open the transmitter front cover and complete the following steps:
STEP 1: Press the PROG button for 4 seconds and release. The words START and For will begin to blink (Fig. 20). The current DAY, PERIOD, TI , ME, and SET temperature of the built-in factory program will also be displayed. To program the DAY and PERIOD OF DAY, press the AHEAD or BACK buttons to display the DAY and PERIOD you wish to program. When you have reached the correct DAY aPERIODRIO OF, DAY push the PROG button and the TIME will blink on the LCD screen (Fig. 21).
STEP 2: To program the START TIME, press the UP or DOWN buttons to set the hour corresponding with the AM/PM time period. Start time settings ar15-minutenutes segments. When the desired START TIME is displayed, press the PROG button,n and the SET temperature will blink on the LCD screen.
STEP 3: To program the SET TEMPERATURE, press the UP orDOWN buttonss. When desired SET temperature displays, then press the PROG button. After pressing the PROG button,n the next PERIOD of the same or next day will display (not blink) on the LCD screen (Fig. 23)
To program the next Period of the day,y follow steps 1 through 3, recording them on the blank table below until all (7) days and the (4) time periods in each day areprogrammedd. Once ALL the programming has been completed, then press the SET button on the transmitter. The programming data you entered will now overridethe fafactory-built-inrogram and operate your system.
ХӨТӨЛБӨРИЙН ТАЙЛБАР:
Once you are in the programming process, if you only want to program specific days, you can bypass the DAYS and PERIOD of DAY by pushing the AHEAD or BACK buttons. This eliminates the need to enter the TIME and TEMPERATURE for each DAY and PERIOD, speeding up the programming process. Once the LCD screen displays the specific DAY and PERIOD of DAY you want to program, press the PROG button and follow the steps above.
ХӨТӨЛБӨР REVIEW
Хэрэв та дахин хийхийг хүсч байвалview the settings for the FACTORY BUILT-IN program or your customized program, you may do so by pressing the PROG button for one second at a time. To review each setting, then press the PROG button one second between each period of the day. Press the SET button when finished reviewing to return to normal operation.
PROGRAM CANCELLATION
If you want to cancel the CUSTOMIZED program you entered and return to the FACTORY program, do the following:
- STEP 1: Press the SET button to ensure the LCD screen is in the normal state.
- STEP 2: Press and hold the PROG and SET buttons “at the same time” for 10 seconds.
- STEP 3: The customized programs will be canceled,d and the LCD screen will begin blinking the START, FOR, TIME, and
- SET temperature confirming the customized programs have been cancelled.
- STEP 4: Push the SET button to return to the normal LCD screen or wait 10 seconds, and it will return automatically.

ДАМЖУУЛАГЧИЙН АЖИЛЛАГААНЫ РЕГИ
CHECKING THERMO OPERATION
The operation of the Thermo setting can be checked on demand by adjusting the SET temperature 2°F above or below the room temperature, which will cause the system to turn ON or OFF, respectively. Normally, however, the system will only respond to temperature changes every two minutes. NOTE: Ifthe “SWING” number has been changed, then activation will occur at the new “SWING” setting. See pages 11 and 12 for more temperature SWING information. When the gas fireplace system is activated, a FLAME icon will display on the LCD screen indicating a signal has been sent from the transmitter.
THERMO MODE OPERATION (System operates as a thermostat based on the SET temperature only)
ӨРӨӨНИЙ ХҮССЭН ТЕМПЕРАТУРЫГ ТОХИРУУЛАХ
This remote control system can be thermostatically controlled when the transmitter is in the THERMO mode.
- To set the DESIRED room temperature, press the MODE button on the transmitter until the word THERMO is visible on the LCD screen. The larger number in the center of the screen is the room temperature, and the smaller number on the right side is the SET temperature.
- Press the UP or DOWN button to select the DESIRED room temperature. The highest SET temperature is 99°F (32°C). The lowest SET temperature is 45°F (6°C).
- The TRANSMITTER will monitor the room temperature every 2 minutes automatically turningthe fireplace ON or OFF thermostatically.

SET TEMPERATURE OVERRIDE – (PROGRAM mode only)
The user may change the current SET temperature without changingthe programs stored in the transmitter’s memory. The OVER-RIDE feature will be automatically cancelled at the start of the next PROGRAM PERIOD.
- To change cthe currentSET TEMPERATURE, press the UP or DOWN button (Setting will be cancelled automatically when the next program period begins.) The word OVERRIDE will appear over the SET frame on the LCD screen.
- To cancel temperature OVERRIDE, press the SET button.

SET TEMPERATURE HOLD – (PROGRAM mode only)
The user may override the SET temperature during any period, adjusting the SET temperature to a CONSTANT new SET/HOLD temperature.
- Press the UP or DOWN button to change the SET temperature to the level desired. The word OVERRIDE will appear in the SET frame on the LCD.
- To HOLD the new temperature at a CONSTANT setting, push the UP and DOWN buttons “at the same time” to activate the HOLD function. The word HOLD will appear over the SET frame, and the word OVERRIDE will disappear.
- To cancel OVERRIDE or HOLD, press the SET button.

TIME OF DAY DISPLAY
- To check the current TIME of day, press the TIMER/TIME button on the transmitter for less than 1 second. The current TIME of day will appear in the TIME/TEMP frame, replacing the temperature reading.
- The TEMPERATURE will reappear in 15 seconds, or you can press the SET button to cancel the display of the time.

ЦАГИЙН ЦАГИЙГ ТОГТООХ
This remote control can operate with the built-i, countdown timer when the transmitter is in the ON or THERMO mode (THERMO or ON must be displayed on the LCD screen). DO NOT operate in PROGRAM MODE, because time is pre-programmed into the transmitter.
- Press the TIMER/TIME button on the transmitter for more than 2 seconds. The word TIMER and 0:15 flash on the LCD screen.
- Press the UP or DOWN button on the transmitter to begin advancing through each of the countdown time options. Available countdown times are 15 min., 30 min, 45 min, 1 hr, 1 hr 30 min, 2 hr, 2 hr 30 min, and each additional half hour up to nine hours.
- To set the TIMER, press the SET button on the transmitter. If the system is ON, it will remain on until the “timer” has expired. If the system is in the THERMO mode, it will cancel ON and OFF, as the room temperature requires, until the “timer time” has expired.
- To cancel the TIMER operation, press the TIMER/TIME button for more than 2 seconds.
OPERATIONAL NOTE: When the TIMER is used in the THERMO mode, the THERMO operation will be disabled until the “countdown time” has expired, thenthe normal THERMO mode will resume.
БАТЕРЕЙН ҮЗҮҮЛЭЛТ
The low battery icon will appear when battery power has dropped significantly. At this time, approximately two weeks of battery power rremain untilthe transmitter may experience partial or complete loss of functions.
NOTE: A reversed battery can activate the LOW battery icon.

ADDITIONAL PROGRAMMING – OPTIONS TO CHANGE SWING TEMPERATURE
The thermo-transmitter operates the fireplace system whenever the ROOM TEMPERATURE varies a certain number of degrees from the SET TEMPERATURE. This variation is called the “SWING” or TEMPERATURE DIFFERENTIAL. The normal operating cycle of a fireplace system may be 2-4 times per hour d, depending on how well the room or home is insulated from the cold or drafts. A smaller “swing number” increases the number of cycles, so the room temperature is more constant. A larger “swing number” decreases the number of cycles, which saves energy, in most cases. The factory set-ting for the “swing number” is 2. This represents a temperature variation of +/- 2°F (1°C) between the SET temperature and the ROOM temperature, which determines when the fireplace will be activated. The “SWING” number values are: 1= +/- 1°F (.5°C), 2= +/- 2°F (1°C), 3 = +/-3°F (1.6°C).
- To change the temperature “SWING” setting (1-3), press the AHEAD & BACK buttons “simultaneously” to display the current “SWING.”
- Setting in the SET TEMP frame. The word SWING will display on the LCD screen.
- Press the UP or DOWN button to change the temperature differential or “SWING” (1-3). See above for 1-3 “SWINGtemperaturere values.
- To store the “swing number”, press the SET button or allow 15 seconds to lapse, and the new “swing number” will be automatically programmed.

MANUAL CHECK OF “SWING” OR TEMPERATURE DIFFERENTIAL
The operation of the factory set “THERMO SWING” can be checked by adjusting the SET TEMP 2°F above or below the room temperature. This will cause the system to turn ON or OFF. Normally,y the system will only respond to temperature changes every two minutes. Manually changing the SET temperature will activate the system in less than 10 seconds. If the “SWING” is changed, then a new room temperature differential will respondThe factoryry setting of SWING temperature is 2°F.
OPERATIONAL NOTE: TO CONSERVE BATTERY POWER, CHANGES IN TEMPERATURE ARE ONLY RECORDED EVERY TWO MINUTES. Additionally, to prevent repeated thermo-cycling of gas appliance, the sensing unit in the transmitter will only activate the remote receiver when temperature change exceeds 2°F (1°C) above or below the SET (desired) temperature. However, if the “SWING” setting has been changed from the factory setting (2°F /1°C), then thermo-cycling will activate at the new setting of the “SWING” number.
CHILDPROOF “LOCK –OUT” – (CP)
This remote control includes a CHILDPROOF(CP) “LOCK-OUT” feature that allows the user to disable the operation of the fireplace from the TRANSMITTER when any button is pressed.
“ТҮГЖҮҮЛЭХ”-ИЙГ ТОХИРУУЛАХ – (CP)
- To activate the “LOCK-OUT” feature, press and hold the UP and TIMER/TIME buttons together,for 5 seconds. The letters CP will appear in the TEMP frame on the LCD screen.
- To disengage the “LOCK-OUT”, press and hold the UP and TIMER/TIME buttons together for 5 seconds or more, and the letters CP will disappear from the LCD screen and the transmitter will return to its normal operating condition.

NOTE: If the fireplace system is already operating in the ON, THERMO, or PROGRAM MODES, engaging the “LOCK-OUT” will not cancel the operating MODE. Engaging the “LOCK-OUT” prevents only the manual operation of the TRANS-MITTER. If in the auto modes, the THERMO and/or PROGRAM operation will continue to operate normally. To totally “LOCK-OUT” the operation of the TRANSMITTER’S operating signals, the transmitter’s MODE must be set to OFF.
Үзүүлэлтүүд
- BATTERIES: Transmitter 3.0V- 2 ea. AAA 1.5V, Alkaline Remote Receiver 6V – 4ea. AA 1.5 Alkaline
- FCC ID No.’ transmitter –K9L3301TX; receiver – K9L301RX
- Үйлдлийн давтамж: 303.8 МГц
- Canadian IC ID No.: transmitter – 2439-3301TX; receiver – 2439A-3301RX
FCC-ийн ШААРДЛАГА
NOTE: THE MANUFACTURER IS NOT RESPONSIBLE FOR ANY RADIO OR TV INTERFERENCE CAUSED BY UNAUTHORIZED MODIFICATIONS TO THIS EQUIPMENT. SUCH MODIFICATIONS COULD VOID THE USER’S
AUTHORITY TO OPERATE THE EQUIPMENT. For warranty information,n please contact the gas appliance supplier for this product.
ШУУРХАЙ ТОХИРУУЛАХ ГАРЫН АВЛАГА
FOR Model 3003P PROGRAMMABLE TRANSMITTER
This guide is ashortcutu” method to SETUP and OPERATE the programmable transmitter. For detailed instructions for each feature and function, see OWNE’ SS MANUAL.
INITIAL SET-UP FUNCTIONS USING BUTTONS ON THE FRONTOF THE TRANSMITTERR
OPERATION – Press the MODE button on the TRANSMITTER to change operating functions.
- ON indicates the system is ON, either manually or thermostatically.
- OFF нь систем бүхэлдээ унтарсан байгааг илтгэнэ.
- THERMO indicates the system will automatically cycle ON/OFF thermostatically depending on the programmed SET temperature.
- PROG indicates the system is operating with PROGRAM settings.
OTHER OPERATIONS – Press corresponding buttons on TRANSMITTER to activate functions.
- TIME OF DAY – Press & release
- TIMER/TIME button for less than 1-second.
- TIME OPERATION – Press and hold the TIMER/TIME button for 2-seconds.
- COUNTDOWN TIME — pressing UP or DOWN buttons.
NOTE: Press the SET button to stop the LCD digits from flashing.
For detailed instructions for each feature and function, see OWNER’S MANUAL. The transmitter has a built-in factory program, (7) days a week, with (4) continuous time periods for each day. Each time period hasitss own starting time and temperature. A chart of the built-in programs is shown below. NOTE: The ending time for one period is the starting time for the next period.
SHORT-CUT PROGRAMMING
- Press the PROG button for more than 4-seconds. The words START and FOR on the LCD will begin blinking.
- Program DAY OF WEEK and PERIOD OF DAY by press ing AHEAD and BACK buttons.
- Again, press the PROG button. START TIME will begin blinking. Program START TIME by pressing the UP or DOWN button.
- Again, press the PROG button. SET TEMP will begin to blink. Program SET TEMP by pressing UP or DOWN buttons.
- Again, press the PROG button. The next DAY OF WEEK and PERIOD OF DAY will begin to blink.
- Repeat steps 2 through 5 for all 7 DAYS until each PERIOD OF DAY is programmed.

When all programmed settings are complete, press the SET to lock in new programs. To REVIEW, either FACTORY or USER programs, push the PROG button for 1-second; then scroll through each DAY and PERIOD OF DAY by pressing the PROG button, allowing 1-second between each press of this button. Press the SET button when finished reviewing the programmed times and temperatures. To CANCEL user-customized programming, press and hold PROG and SET buttons together for 10-seconds; all USER programs will be cancelled,a nd the FACTORY program will return.
NOTE: Push AHEAD or BACK buttons to advance day and period, should you not want to change each SET time or SET temperature.